NOTE!
The current, compared to the nominal capacity, is given in coulombs
(C), e.g. 0.2 C for a 100 Ah battery results in 20 A.
LK10-05 - Freely ventilated lead-acid
Fig. 6: Charging characteristic LK10-05
In the “Top-Fill” charging phase, the battery is charged with +15% more current
compared to the main charging phase.
In the range [-30 °C ... -35 °C] and [+45 °C ... +60 °C] the current is reduced to
0.
Voltage per cell
12 V system
24 V system
2.4 V/ 2.8 V/ 2.29 V
14.4 V/ 16.8 V/ 13.74 V
28.8 V/ 33.6 V/ 27.48 V