Страница 2: ...16 18 Getting Started 19 Installation 19 Power Up 19 Web App UI 20 27 Connecting to the Network 21 Setting up the Web App UI 22 27 Saving Amplifier Settings 28 Loading Amplifier Settings 29 Saving Cha...

Страница 3: ...of great experiences So we are dedicated to providing perfect sound reinforcement through all of our products We re deeply proud of our Connect Series amplifiers and we can t wait for you to get work...

Страница 4: ...I N T R OD U C I N G T H EWOR L D SF I R S TI OT E N A B L E DP R OF E S S I ON A LA MP L I F I E R S...

Страница 5: ...adding monitoring and preventative system maintenance to their service contracts Also included is an Analog Devices 96kHZ DSP with up to 48dB Oct filters 8 parametric EQ s speaker protection limiting...

Страница 6: ...ad Monitoring Realtime Load Monitoring and Pilot Tone Detection from Internal or External Sources Control Monitoring Network Network Connectivity WiFi or 100MB Ethernet with PoE or Built in WiFi Acces...

Страница 7: ...2019 LEA Professional All Rights Reserved 6 Front to back airflow See previous page for fan noise SPECIFICATIONS ProductData CONTINUED 19 482mm 1 72 43 7mm 14 2 360 7mm...

Страница 8: ...luded by advanced replacement with new or equivalent factory refurbished product during the initial three year warranty period LEA LLC will provide ground shipment for the replacement product free of...

Страница 9: ...ngest just above and below the unit If an equipment rack is used we recommend installing the amplifier s in the bottom of the rack and the preamplifier or other sensitive equipment at the top BE AWARE...

Страница 10: ......

Страница 11: ...ght the channel is heavily limiting the output Channel Clip A red light indicates the channel is at the onset of audible clip on the output Excessive clipping can damage the speaker connected to the a...

Страница 12: ......

Страница 13: ...l e c t a b l eb yc h a n n e l 5 C h a n n e l A t t e n u a t o r s C H 1 C H 2 C H 3 C H 4d e t e n t e da t t e n u a t i o np o t s 6 A n a l o gB a l a n c e dI n p u t s C H 1 C H 2 2 6d Ba n d...

Страница 14: ...C H 1 C H 2 C H 3 C H 4 2 6d Ba n d3 4d Bi n p u t s e n s i t i v i t y 5 C h a n n e l Ou t p u t C H 1 C H 2 C H 3 C H 4 L o w Z 7 0 V o r 1 0 0 Vs e l e c t a b l eb yc h a n n e l 6 B u i l t i...

Страница 15: ...n n e l 5 C h a n n e l A t t e n u a t o r s C H 1 C H 2 C H 3 C H 4d e t e n t e da t t e n u a t i o np o t s 6 A n a l o gB a l a n c e dI n p u t s C H 1 C H 2 C H 3 C H 4 2 6d Ba n d3 4d Bi n p...

Страница 16: ...C H 3 C H 4 C H 5 C H 6 C H 7 C H 8 2 6d Ba n d3 4d B i n p u t s e n s i t i v i t y 5 C h a n n e l Ou t p u t C H 1 C H 2 C H 3 C H 4 C H 5 C H 6 C H 7 C H 8L o w Z 7 0 V o r 1 0 0 V s e l e c t a...

Страница 17: ......

Страница 18: ...k Input Connectors 2 for analog input 1 for External I O Port 2 2 position 7 62mm Amphenol Anytek Output Connectors 4 Rack Screws standard 2 Rear Rack Supports 4 CHANNEL KIT Connect Series 84D Connect...

Страница 19: ...Part CPP10001 1 350 700W Only 2 Position Amphenol Anytek Output Connector LEA Part CPP10006 1 80 160W Only 3 Position Amphenol Anytek Input Connector LEA Part CSP10006 1 3 Position Amphenol Anytek Inp...

Страница 20: ...n the front panel This is intentional and prevents unwanted adjustments 2 To power on the unit on the back you will notice an icon that looks like this Once you press this button you will notice a LED...

Страница 21: ......

Страница 22: ...ple amplifiers in the Web Browser Based UI Using 10 100MB FAST Ethernet 1 Connect via wired network using Cat5 or Cat6 cable 2 Once connected the front LCD now displays an IP address 3 Connect your de...

Страница 23: ...s of every channel on any given amp to quickly monitor channel performance Such as your output meter with a clip indicator status indicators such as Ready Limiting Thermal and Fault as well as a quick...

Страница 24: ...LL SEE THIS LOGIN SCREEN ONCE THE CORRECT PASSWORD IS ENTERED OR IF GUEST MODE IS SELECTED YOU WILL BE TAKEN TO THE HOME SCREEN SHOWN ABOVE FIRST TIME USERS WILL IMMEDIATELY SEE THIS SCREEN THIS IS TH...

Страница 25: ...1 Normal operation No errors or faults reported State 3 The amp is reporting a fault State 2 Amp reporting an event but no faults State 2 Amp connected via rear panel ethernet connection State 1 Amp...

Страница 26: ...e power cord with a leaf icon brings you to the Green Menu page Pressing the Wi Fi or LAN icon brings you to the Network Settings page Pressing the distressed face emoji brings you to the Faults Log p...

Страница 27: ...Reserved 26 WEB APP UI PageGuide CH 1 Output Mute CH 1 Output Meter CH 1 Ready Indicator CH 1 Limiting Meter CH 1 Attenuation always read only CH 1 Output Clip Indicator CH 1 Fault Indicator CH 1 The...

Страница 28: ...B APP UI PageGuide CONTINUED J U S T 3 C L I C K S A W A Y F R O M A N Y T H I N G T A P T H R O U G H T H E I C O N S T O G E T T O C H A N N E L S E T T I N G S INPUTS CH SETTINGS SIGNAL GENERATOR C...

Страница 29: ...APP UI PageGuide CONTINUED SAVE AMP FILES CLICK THE i ICON FROM THE AMP S MAIN SCREEN 1 2 SELECT ADVANCED FROM THE POPUP MENU PRESS EXPORT AMP SETTINGS 3 4 A FILE WILL BE DOWNLOADED TO YOUR MAC WINDO...

Страница 30: ...SID Password DHCP or Static If Static IP address and Gateway will be loaded Ethernet DHCP or Static If Static IP address and Gateway will be loaded CHANNEL SETTINGS This check box will load the follow...

Страница 31: ...NEL YOU WISH TO SAVE TUNINGS FROM 1 2 NAVIGATE TO THE CROSSOVER SETTINGS PAGE AND SELECT EXPORT SELECT EXPORT AGAIN AND YOUR SETTINGS WILL BE DOWNLOADED TO YOUR DEVICE 3 THE DOWNLOAD FILE WILL CONTAIN...

Страница 32: ...INDOWS PC OR ANDROID DEVICES IOS compatibility coming soon FROM THE AMPLIFIER MAIN SCREEN SELECT WHICH CHANNEL YOU WISH TO SAVE TUNINGS FROM 1 3 NAVIGATE TO THE CROSSOVER SETTINGS PAGE AND SELECT IMPO...

Страница 33: ...3 2...

Страница 34: ...ectable by channel LowZ HiZ mode in the web browser based UI If you have a low impedance load select the LowZ mode for that channel If you are running a 70V load select HiZ 70V If you are running a 10...

Страница 35: ...r protection limiter will automatically enable itself The amplifier protection limiter can enable itself if the amplifier is running in the upper limits of its thermal capacity or if AC voltage drops...

Страница 36: ...ages www leaprofessional com products If you don t see an API for your system please send your API request to us at salesandmarketing leaprofessional com Universal Switch Mode Power Supply with PFC Th...

Страница 37: ...s 1 4 Power 201 59 222 65 188 55 208 61 198 58 BTU Hr Watts 1 8 Power 164 48 171 50 157 46 164 48 160 47 120VAC 8 ohm 4 ohm 2 ohm 70V 100V 4 x 80W 4 x 80W 4 x 80W 4 x 80W 4 x 80W Output Power AC Power...

Страница 38: ...76 303 89 227 80 248 73 239 70 BTU Hr Watts 1 8 Power 204 60 221 65 214 63 204 60 199 58 120VAC 8 ohm 4 ohm 2 ohm 70V 100V 2 x 350W 2 x 350W 2 x 350W 2 x 350W 2 x 350W Output Power AC Power Consumpti...

Страница 39: ...9 96 246 72 296 87 280 82 BTU Hr Watts 1 8 Power 212 62 233 68 191 56 216 63 205 60 240VAC 8 ohm 4 ohm 2 ohm 70V 100V 8 x 80W 8 x 80W 8 x 80W 8 x 80W 8 x 80W Output Power AC Power Consumption Amps Wat...

Страница 40: ...raining videos and several helpful FAQs that might answer any questions you may have Also feel free to contact us directly any time at customercare leaprofessional com 1 574 207 4220 LEA LLC 635 S Laf...

Страница 41: ...extend your warranty to 6 years here LEA Product Registration https leaprofessional com lea product registration Warranty outside the U S is honored by the Authorized Distributor in a specific countr...

Страница 42: ...erials we decide to use and which companies we decide to partner with to reduce waste and maximize sustainable efforts Our Browser Based Web UI emPowers users to Know More about the performance of the...

Страница 43: ...vironmental sustainability Go ahead and take a moment to feel good about yourself The amplifier itself is fully ROHS compliant and does not include any lead or other harmful chemicals known to harm th...

Страница 44: ...Voltage Supply Systems Rated Current 16A EN 55032 2012 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE Radiated Class B Limits Conducted Class B EN 55103 2 2009 Electroma...