www.lemaitrefx.com
A routine maintenance program is essential for the optimum per-
formance of your Neutron XS Hazer. We recommend that the tube
maintenance program be applied at least every 25 hours of use, or
when a noticable decrease in output is observed. More frequent
maintenance will result in superior trouble free operation.
To make your maintenance regime more convenient and effective,
a Neutron Cleaning Kit is available from your Le Maitre dealer.
Included in this kit are extra abrazors, cleaning solution, and a
spare Processing Tube. To order this kit use Part #
CXP 2486.
Warning !
Make certain the power cord is unplugged
when servicing this unit. Failure to disconnect
may result in fatal electric shock, fire, or injury to
persons.
To avoid possible burns allow sufficient time for the
unit to cool.
1.) Disconnect power by unplugging unit from main power sup
ply.
2.) Remove top cover by loosening knob fasteners counter
clockwise.
3.) After removing top cover by sliding towards the
front and upwards, the lid will locate into notch
and lift away. Locate the Abrazor tool from behind
label, and remove.
Knob Fastener
Knob Fastener