lemaitrefx.com
5)
The Remote Display will now enter its standard phase. This indicates the ‘Heating’
power, the ‘Flow’ rate setting, and the ‘Ready’ status.
At this stage the flow rate may be adjusted freely between minimum and maximum
settings. (Upon entering a ‘ready to operate’ phase the maximum allowable flow rate will be
automatically adjusted based on the energy available. )
6)
The Timer controls are of an auto-display option, and will display immediately upon
being adjusted, or if set to any position apart from the Interval being ‘Off’ will display
approximately every 10 seconds.
The ‘Interval’ control ( time between repeating fog issues ), allows the following
selection:
‘OFF’
-
No timer or time display
‘1-SH’
-
Single issues upon Fog activation
’00:10'
-
Timer selection in 10 second steps
’05:00'
-
to 5 Minutes, then 30 second steps
’20:00'
-
to 20 Minutes.
The ‘Duration’ control ( time of actual fog issue ) allows the following selection:
’00.02'
-
Timer selection in 2 second steps
’00.30'
-
to 30 Seconds then 30 second steps
’08.00'
-
to 8 Minutes.
Note that when the automatic display of the timer settings occurs, the Interval time
will have a central colon (:) whereas the Duration time will have a central point (.) displayed.
7)
As the machine heats up to its operating temperature, if the flow setting has been set
to maximum, there will be a point when this will readjust to a much lower value. It is at this
point that the machine has reached its lowest ‘ready’ point. A flashing ‘H’ or ‘G’ will appear
in the ‘Ready Flash’ window, indicating that the machine is now ready at its minimum level.
The machine can in fact be operated at this point, or further time allowed for maximum issue
capabilities. If the machine is allowed further time, then the ‘Flow’ rate will be seen to
increase in its allowable maximum setting until position 31 is reached.