G300 Industrial Hose Option
1. Remove G300 cover and existing fluid assembly
2. Drill hole in front control panel to accept key switch
Figure 1
. Solder wires from G300
mode button to Pins 1 and 3 on key switch (be careful not to over-heat the switch).
3. Take the long end of the black hose and feed up through the existing hole
Figure 2
. (from
inside out) Be sure to use the hole plug provided to permit the hose clamp from protruding
through the hole.
4. Slide on the strain relief and insert the brass filter
Figure 3
. To adjust the depth of the hose
simply loosen nut ‘A’ and slide up or down the hose and retighten. Be careful not to pinch
off the flow of fluid.
5. Make all conncetions to the pumps using gear clamps provided and replace lid.
Note: A dry hose can take between 45 - 60 seconds to prime. This is normal because of the
inside diameter of the hose.