LDK Installation Guide for Photovoltaic Solar Modules – Version: April 2011 

All rights strictly reserved reproduction or issue to third parties in any form what ever is not permitted without written authority from the proprietor. 

1.4 Limited warranty 
 

Module warranty conditions are described in the LDK Solar document: LDK Solar Limited Warranty for 
PV Module
.   

Ignoring  the  instructions  and  considerations  described  herewith  can  be  a  cause  by  LDK  Solar  to 
invalidate  the  warranty  in  case  of  provable  negligence.  Please  contact  to  the  Technical  Support 
Service for any question s about warranties.     
 

2

  SAFETY 

 

LDK Solar PV modules have passed all required safety tests and certification according to the IEC 
61730 with Application Class A, and as Safety Class II according to the IEC 61140. Fire safety has 
been rated as Class C, reaching all requirements to be mounted on Class A roofs.   
 

2.1 General Safety 

 

   All  PV  modules  should  be  installed  according  to  all  local  and  national 

applicable standards, codes and regulations. 

   Installation  should  be  performed  only  by  qualified  persons.  Installers 

should  assume  the  risk  of  all  injury  that  might  occur  during  installation, 
including, without limitation, the risk of electric shock. 

   Check and follow all safety precautions specified for other components of 

the system. 

   Rooftop installations should be placed over fire resistant roofs only. 

   Do  not  attempt  to  disassemble  the  modules,  and  do  not  remove  any  attached  nameplates  or 

components from the modules. 

   Do not apply paint or adhesive to module top surface. 

   Do  not  use  mirrors  or  other  magnifiers  to  artificially  concentrate  sunlight  on  the  modules.  Do  not 

expose back sheet foils directly to sunlight. 

 

2.2 Handling Safety 
 

   Do not stand or step on module. 

   Do not drop module or allow objects to fall on module. 

   To avoid glass breakage, do not place any heavy objects 

on the module. 

   Do not set the module down hard on any surface. 

   Inappropriate transport and installation may break module. 

 
 

2.3 Installation Safety 
 

   Installing solar photovoltaic systems requires specialized skills and knowledge.   

   One individual module may generate DC voltages greater than 30 volts when exposed to direct 

sunlight. Contact with a DC voltage of 30V or more is potentially hazardous. 

   Do not disconnect under load. 

   It is recommended to completely cover the module with an opaque material during installation to 

keep electricity from being generated. 

   Do not wear metallic rings, watchbands, ear, nose, lip rings or other metallic devices while installing 

or troubleshooting photovoltaic systems. 

   Use only insulated tools that are approved for working on electrical installations. Abide with the 

safety regulations for all other components used in the system, including wiring and cables, 
connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc. 

   Use only equipment, connectors, wiring and support frames suitable for a solar electric system. 

Always use the same type of module within a particular photovoltaic system. 

   Do not attempt to repair any part of the PV module. 

 

3

INSTALLATION 

 
3.1 Design considerations 
 

LDK Solar PV modules should be installed in a location where they will receive the maximum amount 
of sunlight throughout the year. In the Northern Hemisphere modules should face south, while in the 
Southern Hemisphere modules should face north.    Therefore, modules facing more than 30 degrees 
away from true South (or North) could lose approximately from 10% to 30% of their power output. 
 
LDK Solar PV modules connected in series should be installed at same orientation and angle. Different 
orientation or angles may cause a loss of power output due to the change in sunlight exposure. 
 
To develop the final distribution of the modules conforming the photovoltaic system, consider to keep 
suitable access to allow the maintenance and inspection works. 
 
LDK Solar modules series must be installed in the following conditions: 
 
Operating ambient temperature:        -40°C to +85°C   
Storage temperature:                         -40°C to + 60°C 
Humidity:                                                below 85RH%   
 
When installing a module on a roof or building, ensure that it is securely fastened and cannot fall as a 
result of wind or snow loads and provide adequate ventilation under a module for cooling 
(recommended 10cm minimum air space between module and mounting surface). 
 
LDK Solar modules are not allowed to be mounted in mobile applications or in marine environments 
with direct contact with salty water, please avoid installing the modules on places directly exposed to 
the sea. 

 

Figure 2. 

 

Provide adequate ventilation under a module 

Содержание LDK-160D-24s

Страница 1: ...ed by implication or otherwise under any patent or patent rights The information in this manual is based on LDK Solar s knowledge and experience and is believed to be reliable but such information including product specification without limitations and suggestions do not constitute a warranty expresses or implied LDK Solar reserves the right to change the manual the PV product the specifications o...

Страница 2: ...may generate DC voltages greater than 30 volts when exposed to direct sunlight Contact with a DC voltage of 30V or more is potentially hazardous Do not disconnect under load It is recommended to completely cover the module with an opaque material during installation to keep electricity from being generated Do not wear metallic rings watchbands ear nose lip rings or other metallic devices while ins...

Страница 3: ...he Annex 1 to get more information about the use of mounting holes and load resistance of all module types Figure 3 Frame holes mounting 3 2 2 Pressure clips mounting The modules should be fixed to the structure by pressure clips on the large side or short side of the frame according to instructions on Annex 1 The clips must be mounted at the position of the mounitng hole with a 10 of total length...

Страница 4: ...and properly formed personnel Check the open circuit voltage of every series module by a digital multimeter The measured values should correspond to the sum of the open circuit voltage of the individual module You will find the rated voltage in the technical specifications of the type of the module used If the measured value is significantly lower than the expected value please proceed as describe...

Страница 5: ...4 LDK 250 290 P 24 s A 1580 1580 1642 1630 1642 1630 1958 1946 B 808 808 994 976 994 976 994 976 C 390 390 421 415 421 415 579 573 D 140 140 171 165 171 165 329 323 E 40 40 40 40 40 40 50 50 F 30 30 30 30 30 30 40 40 Cable 950 950 1000 1000 1000 1000 1200 1200 Weight kg 15 6 15 6 20 19 20 19 30 5 27 3 Cell type Mono 125 Multi 125 Mono 156 Mono 156 Multi 156 Multi 156 Multi 156 Multi 156 Num of Cel...

Страница 6: ...ide System 1 Installation with mounting holes All module types 5400Pa Normal Installation System 2 Installation with pressure Clips A Clips System on large side B Clips System on short side All module types 5400Pa Installation according to drawing specification All module types 2400Pa Pressure clips on short side All module types Not allowed for 5400 Pa System 3 Insertion Systems A Insertion Syste...

Отзывы: