MPS-8Z connection to an audio system with ZES-22
This functionality is supplemented by the LDA ZES-22 ACSI S01 adapter. As shown in
Picture 4: LDA ZES-2 ACSI S01 Adapter, the RJ-45 connector allows direct connection to
the MPS-8Z microphone input, as well as powering it; via the local power supply of the
adapter itself.
1.3
Connection to multiple MPS-8Z
The microphone has two connections for distributed elements in public address
systems. It consists of a line-level audio input plus control signals, for connection of up to 8
devices in "daisy chain" bus mode, where each device is connected to the next. Both
connections are identical and interconnected. This connection must be made from the
output of one microphone to the input of the next (in Picture 5: Detail of MPS-8Z
microphone connections, the OUT and IN connectors respectively of ACSI BUS).
The connection of the adapter to the microphone is made by means of an ethernet
cable, standard T568B. The maximum connection distance for the entire bus is 1000m
(3280ft), with up to 8 MPS-8Z devices connected to the ZES-22.
Picture 3: ZES-22 Audio Matrix Connections
2º )
1º )
Picture 4: LDA ZES-2 ACSI S01 Adapter