background image

Connection to public address system with SIME (MPS-8Z with ZES22 matrix)

Support Handbook - LDA MPS-8Z S02

 1.2 

RS-485 Connection

In order to properly connect MPS-8Z microhone and ZES-22, it is mandatory to do it by an
specific UTP cable. This cable should be CAT 5 or higher.
Starting with the attached diagram (Picture 3), the next connection must be followed 

This will be the input connector for MPS8-Z Microphone (ACSI bus). 

Next step, the wiring connection to ZES-22 must follow this pinout indicaions:

1. (Striped Orange): Audio +

2. (Orange): Audio -

3. (Striped Green): GND

4. (Blue): RS-485 A

5. (Striped Blue): RS-485 B

6. (Green): GND

7. (Striped red): + 24 V

8. (Red): + 24 V

This wiring must be connected by a three ways Euroblock connector, getting split  two
connector for RS-485 and audio input ports.

As shows on Picture 4 indications,  this wires connect to tags number 4 (input/output
ZES-22 ports) and number 8 (RS-485). Furthermore, the audio input CH3 must be the

used one for a correct setup.

Picture 3: RJ45 Type B pinout diagram

Содержание MPS-8Z S02

Страница 1: ...Support Handbook Connection to public address system with SIME MPS 8Z with ZES22 matrix Reference LDA MPS 8Z S02...

Страница 2: ...y from the ACSI bus through its connection to the bus At this case save the power supply for use it later 1 1 1 POWER SUPPLY SELECTION MPS 8Z systems have a power supply DIP Swicth selector that allow...

Страница 3: ...Z Microphone ACSI bus Next step the wiring connection to ZES 22 must follow this pinout indicaions 1 Striped Orange Audio 2 Orange Audio 3 Striped Green GND 4 Blue RS 485 A 5 Striped Blue RS 485 B 6...

Страница 4: ...apter 1 3 Connecting severals MPS 8Z units MPS 8Z systems counts with several PA elements It consists of an audio input at line level plus control signals for connection of up to 8 devices in daisy ch...

Страница 5: ...M button for at least 2 seconds Access to the address setting will be confirmed by flashing the LINK and EMG indicators The configured bus address will be indicated by lighting the associated zone mem...

Страница 6: ...n a chime will be played before the microphone is open to talk To confirm the new configuration press TALK to cancel press CANCEL 1 4 3 CONFIGURATION EXTERNAL MICROPHONE The zone 3 button enables disa...

Страница 7: ...ight will remain on When the volume level is at the minimum the zone 8 light will remain on To confirm the new configuration press TALK to cancel press CANCEL 2 SYSTEM REQUERIMENTS ZES 22 firmware 1 0...

Отзывы: