DEVICE CONFIGURATION (SETUP)
Menu item for editing device configuration, reading device firmware, resetting the device and managing global presets. Press the rotary
MENU
dial to access the selection menu for device settings and turn the dial to select the menu item
SETUP
(bright background). Confirm by
pressing the dial.
This will take you to the sub-menu with the following menu items (turn the MENU dial to select, then confirm by pressing MENU):
SETUP
FIRMWARE
The device firmware version is displayed in the top line of the display.
NAME
Configure individual amplifier name
(8 digits):
Press the MENU dial -> Turn the MENU dial to select 1 to 8 -> Press MENU -> Rotate MENU to select letters,
numbers, or characters -> Press MENU -> To exit, rotate MENU dial clockwise to arrow icon -> Press MENU.
PIN
ON / OFF / EDIT
Activate automatic locking of controls to prevent accidental and unauthorised
operation
(except MASTER VOLUME, if enabled):
Press MENU twice -> Rotate MENU to
ON
-> Press MENU -> To exit, rotate MENU to arrow symbol -> Press
MENU
Deactivate automatic locking:
Enter PIN to unlock menu (4-digit PIN factory setting: 1234) -> Rotate MENU to SETUP -> Press MENU ->
Rotate MENU to PIN -> Press MENU twice -> Rotate MENU to
OFF
Press MENU -> To exit, rotate MENU to
arrow symbol -> Press MENU
Set personal PIN:
Press MENU twice -> Rotate MENU to
EDIT
Press MENU -> Rotate MENU to select 0 - 9 for first digit -> Press
MENU -> Rotate MENU to select 0 -9 for second digit -> Press MENU etc. In the event of the PIN becoming
lost, it can be reset to the factory setting (1234) by using the PC software and USB interface (downloadable
from the product page at WWW.LD-SYSTEMS.COM).
DELAY UNIT
METRES / FEET
Configuring unit of measurement for channel delay METRES/FEET:
Press MENU -> Rotate MENU to select
METERS
or
FEET
-> Press MENU -> To exit, rotate MENU to arrow
symbol -> Press MENU
DELAY TEMP
Configuring distance calculation based on air temperature
(sound speed is dependent upon air
temperature):
Press MENU twice -> Rotate MENU to select temperature from 0°C to 40°C -> Press MENU -> To exit, rotate
MENU to arrow symbol -> Press MENU
CONNECT GND
YES / NO
Floating switching for disconnecting the signal ground from equipment grounding
(to prevent ground loops):
Press MENU twice -> Rotate MENU to
YES
for ground connection /
NO
for ground lift -> Press MENU -> To
exit, rotate MENU to arrow symbol -> Press MENU
FACTORY SETTING
NO / YES
Reset to factory settings
(e.g. resetting PIN to 1234 and OFF):
Press MENU -> Rotate MENU to
NO
= do not reset device /
YES
= reset device -> press MENU
GLOBAL PRESET
Save all settings except amplifier name and PIN in global presets
(16 internal memory slots):
Press MENU -> Rotate MENU to
SAVE PRESET
-> Press MENU -> Rotate MENU to desired memory slot ->
Press MENU -> Configure preset name: Rotate MENU to select digit (9 digits) -> Press MENU -> Rotate MENU
to select letter, number or character -> Press MENU etc. -> Rotate MENU to
YES
-> Press MENU -> Rotate
MENU to EXIT to go back -> Press MENU -> To exit, rotate MENU to EXIT -> Press MENU
Loading a global preset from internal memory:
Press MENU -> Rotate MENU to
LOAD PRESET
-> Press MENU -> Rotate MENU to required preset -> Press
MENU -> Rotate MENU to
YES
-> Press MENU -> Rotate MENU to EXIT to go back -> Press MENU -> To exit,
rotate MENU to EXIT -> Press MENU
EXIT SETUP
To exit the setup-menu, rotate the MENU dial to
EXIT SETUP
and confirm by pressing MENU