background image

78-1639-250 

7/14

Lionel

Accessory Switch 

Controller 2 (ASC2) 

Owner's Manual

LCS PDI CABLES

use either connector

AC Power

PROGRAM

A U A

U

SWITCH

ACCESSORY

SWITCH

ACCESSORY

COMM

COMM

4 O

8

4 T

7

3 O

6

3 T

5

2 O

4

2 T

3

1 O

2

1 T

1

Содержание LCS ASC2

Страница 1: ...14 Lionel Accessory Switch Controller 2 ASC2 Owner s Manual LCS PDI CABLES use either connector AC Power PROGRAM A U A U SWITCH ACCESSORY SWITCH ACCESSORY COMM COMM 4 O 8 4 T 7 3 O 6 3 T 5 2 O 4 2 T...

Страница 2: ...alling a new LCS system with NO Command Base 11 Installing additional LCS devices Installing additional LCS devices 12 Configuring Your ASC2 Configuring your ASC2 13 Connect accessory transformer to r...

Страница 3: ...ut this Owner s Manual and are protected under law All rights reserved Lionel LionChief LionChief Plus LEGACY FasTrack TrainMaster Odyssey RailSounds CrewTalk TowerCom DynaChuff StationSounds Pullmor...

Страница 4: ...LCS SER2 for computer control and use of existing Lionel serial devices like the TPC 300 and TPC 400 How it works As you know your Lionel Cab Remote sends commands to your Command Base In turn the ba...

Страница 5: ...two complementary outputs One pair of relays will activate the THRU position with one set of contacts and the other set of contacts will activate the OUT position Each relay is rated at 20 amps When c...

Страница 6: ...DB 9 Cable with Power Supply Every LCS system requires exactly one 6 81499 LCS DB 9 Cable with Power Supply This special cable has three connectors A a DB 9 with a pig tail cable mount power supply c...

Страница 7: ...Restore power to your layout and Legacy Base 6 Plug in the LCS wall pack power supply If using a Legacy command base it must have software rev 1 52 or higher installed Your system should resemble the...

Страница 8: ...SensorTrack or any other Layout Control System product 5 Restore power to your layout and Base 1L 6 Plug in the LCS wall pack power supply Your system should resemble the figure below Once connected a...

Страница 9: ...h a Legacy Command Base an original TMCC Command Base and a Legacy Serial Y Cable 1 Turn off power to your layout Legacy Base and TMCC TrainMaster command base 2 Connect the DC wall pack to the female...

Страница 10: ...tup you can control Lionel locomotives and Layout Control System products using any combination of LEGACY Remotes CAB 1L remotes and original CAB 1 remotes If you have additional LCS devices to instal...

Страница 11: ...9 connector of the LCS DB 9 Cable unconnected 5 Plug in the LCS wall pack power supply With this setup you can control other Layout Control System products using compatible software on smart devices...

Страница 12: ...ch new device is connected via LCS PDI cables in a daisy chain fashion one to the next and so on The order of devices in the chain is up to you The only exception is that an LCS WiFi must be the first...

Страница 13: ...either connector D Red LCS PDI activity indicator E Program switch used to set the ASC2 s TMCC ID F Relay Power terminals Figure 8 ASC2 callouts There are three additional steps required to use your A...

Страница 14: ...or accessories the ASC2 will switch on and off the power to these connected devices However the power to these external devices will simply be passing through the ASC2 relays The ASC2 does NOT supply...

Страница 15: ...ssories and or lights vs using an ASC2 exclusively to control up to 8 independent uncoupling tracks For switches the sub mode chooses between quick operating switches like FasTrack or slow acting swit...

Страница 16: ...ual for your switch if you are unsure which mode to use Choosing the wrong mode can prevent a switch from throwing or permanently damage it Constant Latching operation is also appropriate for signal c...

Страница 17: ...numbers 3 Press AUX1 to activate the associated accessory on a momentary basis holding AUX1 as long as you desire to keep the accessory operating If you are close to your ASC2 listen for the sound of...

Страница 18: ...switch if you are unsure which mode to use Choosing the wrong sub mode can prevent a switch from throwing or permanently damage it To operate your ASC2 in SWITCH mode Note 1 Turn power to your command...

Страница 19: ...his device simply acts as an ON OFF switch It is recommended that the ASC2 COMM connection be used for the hot leg of your external power To connect a basic on off accessory or light to your ASC2 Note...

Страница 20: ...a basic on off accessory or light to your ASC2 1 Attach one wire to the Power A terminal on your power supply and connect it to the COMM terminal of the ASC2 2 Attach another wire to the Common Groun...

Страница 21: ...ector AC Power PROGRAM A U A U SWITCH ACCESSORY SWITCH ACCESSORY COMM COMM 4 O 8 4 T 7 3 O 6 3 T 5 2 O 4 2 T 3 1 O 2 1 T 1 ASC2 6 81327 Power A Ground U Flood Light Tower bottom view Accessory Transfo...

Страница 22: ...te in one direction only To connect an accessory with two motors or lights 1 Attach one wire to the first motor and connect it to a numbered accessory terminal 2 Attach another wire to the second moto...

Страница 23: ...U SWITCH ACCESSORY SWITCH ACCESSORY COMM COMM 4 O 8 4 T 7 3 O 6 3 T 5 2 O 4 2 T 3 1 O 2 1 T 1 ASC2 6 81327 Sawmill bottom view Accessory Transformer U A 1 Press ACC on the CAB remote controller 2 Usi...

Страница 24: ...the CAB 1L remote controller to address the accessory 3 Press AUX2 to turn on the lamps 4 Press AUX2 again to turn them off 5 Press ACC on the CAB 1L 6 Press 8 on the CAB 1L 7 Press and hold AUX1 and...

Страница 25: ...ck section 1 Press ACC on the CAB remote controller 2 Using your CAB remote controller Enter the ASC2 s TMCC ID base address 3 Press the numbered key matching the terminal connected to your track 2 in...

Страница 26: ...or switch sub mode configuration Each switch requires three connections THROUGH OUT and COMMON The switch terminals at the top of the ASC2 will accommodate each of these connections The first switch i...

Страница 27: ...of the 1T and 1O terminals on the ASC2 unit 4 Repeat this process for any additional switches filling the empty switch terminals on the ASC2 in the same way LCS PDI CABLES use either connector AC Powe...

Страница 28: ...rminal on the side Postwar O22 and MPC O gauge 5132 and 5133 center terminal Super O switches single post closest to the motor O 27 and O42 1122 1122e 5121 and 5122 terminal closest to the motor 4 Rep...

Страница 29: ...put a small amount of solder on the ends of these wires and solder a jumper wire to them Wrap this connection with electrical tape to keep it from coming in contact with the coil housing Before you r...

Страница 30: ...inals are the THROUGH and OUT terminals The COMM terminal is the middle terminal Refer to page 18 and set the ASC2 to the momentary power sub mode Constant power will damage the switch LCS PDI CABLES...

Страница 31: ...e shows the Tortoise connected to switch 1 of the ASC2 Refer to page 18 and set the ASC2 to the latching constant power sub mode If the switch operates in the opposite direction simply reverse the 1O...

Страница 32: ...C2 to the momentary power sub mode Latching constant power will damage the switch If the switch operates in the opposite direction simply reverse the 4O and 4T wires at the ASC2 LCS PDI CABLES use eit...

Страница 33: ...te as expected it may be that you have not addressed it by the right TMCC ID Recall that each ASC2 has a base address that you must assign see page 15 Use the base address to determine the specific TM...

Страница 34: ...se Building Routes with a CAB 1L remote Clearing routes You must clear all of the switches that were assigned to an old route ID before building a new one with the same ID 1 Press RTE on the CAB 1L re...

Страница 35: ...LEGACY CAB2 remote Refer to your LEGACY Control System s Owners Manual for information on building routes on the CAB2 remote Firing routes from a LEGACY CAB2 Activating a route will cause your track s...

Страница 36: ...rs when commands are passing through the LCS PDI bus Specifications of the LCS ASC2 Mechanical Size 3 7 x 2 7 x 1 2 Mounting Two 4 pan head sheet metal screws Electrical Input PDI supply current 50 mA...

Страница 37: ...econd accessory base address plus 1 3 Press AUX1 to turn the accessory on for as long as the button is held OR 4 Press and release AUX2 to turn the accessory on and again to turn it off To program you...

Страница 38: ...switch when base address 3 3 Press AUX1 to set the switch to Through position 4 Press AUX2 to set the switch to Out position To program your ASC2 for Tortoise Switch operation on IDs 9 10 11 and 12 1...

Страница 39: ...not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state Instructions for Obtaining Service If service for this Lionel LLC product is...