background image

75.5319.00   20080111 

 

Page 6 of 9 

 

Programming Guide

 

 

 

 

 

The Microwave Motion Sensor (MMS) is equipped with a Motion Tracking Feature (MTF).  The MTF is available when the 
sensor is used in the uni-directional mode.  The MMS is factory preset with the MTF ON.  MTF is recommended for use in 
short vest bule areas to help reduce unwanted door hold-open time.  Refer to the Programming Guide to alter this setting.  
LCN recommends keeping the MTF enabled for all applications.  The detection capabilities perform as follows: 

 

BI-DIRECTIONAL MODE: 

 

 

Detection of all motion towards or away from the sensor. 

 

UNI-DIRECTIONAL MODE: 

 

 

The detector will work in a uni-directional mode at all times regardless of traffic patterns - detecting only motion moving 
toward the sensor. 

OR 

 

UNI-DIRECTIONAL MODE WITH MTF:

  The principle is as follows: 

 

The detector does NOT activate its relay as long as it detects movement exclusively moving away from the detector.  It 
acts like the classic unidirectional detector. 

 

As soon as the MMS detects movement toward the sensor, it automatically switches to bi-directional mode. 

 

The MMS maintains the bi-directional function for approximately 2 seconds following the last detection of motion toward 
the door. 

 

At the end of the 2-second time frame, if the sensor does not detect any further motion, it switches back to the 
unidirectional mode. 

 

 

 
 

 

 

 

Unlock  

 

 Inquire 

 

 Lock

 

 

 

 

 

To UNLOCK the sensor: 
Press the UNLOCK key once. Red LED 

flashes quickly 

 
To LOCK the sensor: 
Press the LOCK key twice, OR press 

once then followed by a 4-digit lock 
code. If less than 4 digits, press 
lock again after the last digit. LED 
goes out when complete. 

 
To INQUIRE the sensor: 
Unlock the sensor, press the desired 

function key, followed by the 
INQUIRY key – the number of 
green flashes corresponds to the 
value. 

 
Default: 0000 
 

 

 

 

Relay Configuration 

 

 

The relay configuration has 4 possible 
output values: 
 

1= Normally Open Relay 
2= Normally Closed Relay 
3=Continuous Detection 
4=Continuous Non-Detection  

 
Default: 

 

 

Default Values 

 

 

After pressing the DEFAULT VALUE key, 
the red LED flashes quickly. After 
pressing a number button, the red LED 
flashes slowly. 
 
1 = Normal Mounting Height (only for 
serial numbers lower than 84000) 
 
2 = Boost Mode, increases sensitivity for 
high mount applications. 
 
9 = Restore default values except lock 
code (for serial number 84000 and 
greater) 
 
 

 

 

 

Number Keys 

 

 

Number keys (0 through 9) are used for 
assigning a value for a given function 

 

 

Adjustment Keys 

 

 

Plus (+) and minus (-) keys are used for 
incremental adjustments to the sensor 

 

Содержание 8310-854

Страница 1: ...y Max contact voltage Max contact current Max switching power 60 VDC 125 VAC 1A resistive 30W DC 60VA AC Hold time 0 5 sec to 9 sec adjustable Temperature range 4 F to 131 F Dimensions 4 75in W x 3 15...

Страница 2: ...e can build up on the human body and then discharge when you touch a board A discharge can be produced when walking across a carpet and touching a board for example Before handling any board make sure...

Страница 3: ...wn in the picture Drill as instructed Pass the cable where indicated 4 Electrical Installation Terminal Connection 1 Red 12 to 24 VAC DC 2 Black 12 to 24 VAC DC 3 White Relay Common 4 Green Relay NO 5...

Страница 4: ...SENSING FIELDS ACCORDING TO THE VERTICAL TILT ANGLE OF THE ANTENNA The sensing fields on the right correspond to the following adjustments wide sensing field antenna vertical angle of the antenna 0 20...

Страница 5: ...E THE DIMENSIONS WIDTH DEPTH OF THE SENSING FIELD DEPEND ON THE MOUNTING HEIGHT The sensing fields on the right correspond to the following adjustments Wide sensing field antenna Vertical angle of th...

Страница 6: ...seconds following the last detection of motion toward the door At the end of the 2 second time frame if the sensor does not detect any further motion it switches back to the unidirectional mode Unlock...

Страница 7: ...one unit Immunity Immunity helps to reduce the chance of unwanted detections due to environmental disturbances 1 Reduced 2 Normal 3 Increased 4 through 9 enhanced immunity for highly reflective enviro...

Страница 8: ...ry Switch to unidirectional mode without MTF and increase the immunity In airlock vestibules the sensor sees the opposite door Increase immunity In airlock vestibules the sensor sees the movement of t...

Страница 9: ...75 5319 00 20080111 Page 9 of 9 Appendix Wiring Diagrams...

Отзывы: