background image

75.5319.00   20080111 

 

Page 1 of 9 

 

 

 

 
 
 

 
 
 

          

 

 

 

 

 

DESCRIPTION 

SPECIFICATION 

Frequency:    

24.125 GHz 

Supply voltage: 

12 to 24 V AC: 

±

 10%:  

12 to 24 V DC: -10% / +30%:  

Mounting height: 

Normal: 7’;   Maximum: 10’-0” 

Tilt angle: 

0  to 90  vertical 
-15  to +15  lateral 

Detection area:   
Wide 
Narrow 

 
13ft (W) x 6.5ft (D) 
6.5ft (W) x 8.2ft (D) (supplied as optional) 

Minimum detection speed: 

2 in/sec.  (measured in axis) 

Power consumption: 

< 2 W 

Standard output relay: 
Max contact voltage 
Max contact current 
Max switching power 

 
60 VDC / 125 VAC 
1A (resistive) 
30W (DC) / 60VA (AC) 

Hold time: 

0.5 sec. to 9 sec. (adjustable) 

Temperature range: 

-4°F to 131°F 

Dimensions: 4.75in 

(W) 

3.15in (H) x 2.0in (D) 

Weight: 

0.5lbs 

Material: ABS 
Housing color: 

Black - Can be painted with non-metallic paint 

Cable length: 

6ft 

 
 
 
 

1 Description 

2 Specifications 

Terminal 
Block

 

Narrow Antenna Storage

 

Manual Set-Up Buttons

 

Wire Passage Hole

 

Planar Antenna

 

Lateral and Angle 
Adj. For Antenna

 

Opening Tab

 

Wire Opening Knockout 
(inside the cover)

 

Front Cover

 

LED

 

 

8310-854     MICROWAVE MOTION SENSOR

USER’S GUIDE

Содержание 8310-854

Страница 1: ...y Max contact voltage Max contact current Max switching power 60 VDC 125 VAC 1A resistive 30W DC 60VA AC Hold time 0 5 sec to 9 sec adjustable Temperature range 4 F to 131 F Dimensions 4 75in W x 3 15...

Страница 2: ...e can build up on the human body and then discharge when you touch a board A discharge can be produced when walking across a carpet and touching a board for example Before handling any board make sure...

Страница 3: ...wn in the picture Drill as instructed Pass the cable where indicated 4 Electrical Installation Terminal Connection 1 Red 12 to 24 VAC DC 2 Black 12 to 24 VAC DC 3 White Relay Common 4 Green Relay NO 5...

Страница 4: ...SENSING FIELDS ACCORDING TO THE VERTICAL TILT ANGLE OF THE ANTENNA The sensing fields on the right correspond to the following adjustments wide sensing field antenna vertical angle of the antenna 0 20...

Страница 5: ...E THE DIMENSIONS WIDTH DEPTH OF THE SENSING FIELD DEPEND ON THE MOUNTING HEIGHT The sensing fields on the right correspond to the following adjustments Wide sensing field antenna Vertical angle of th...

Страница 6: ...seconds following the last detection of motion toward the door At the end of the 2 second time frame if the sensor does not detect any further motion it switches back to the unidirectional mode Unlock...

Страница 7: ...one unit Immunity Immunity helps to reduce the chance of unwanted detections due to environmental disturbances 1 Reduced 2 Normal 3 Increased 4 through 9 enhanced immunity for highly reflective enviro...

Страница 8: ...ry Switch to unidirectional mode without MTF and increase the immunity In airlock vestibules the sensor sees the opposite door Increase immunity In airlock vestibules the sensor sees the movement of t...

Страница 9: ...75 5319 00 20080111 Page 9 of 9 Appendix Wiring Diagrams...