![LCN 4600CS Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/lcn/4600cs/4600cs_installation-instructions-manual_681909009.webp)
Page 9
DOOR CLOSER HYDRAULIC REGULATION &
POWER ADJUSTMENT
1.
CLOSING SPEED ADJUSTMENT:
(See
Fig. 9
)
The hydraulic regulation of the 4600CS series has been
adjusted prior to shipment. To meet ANSI A156.19 table 1
requirements, open door to 90° and determine the closing time.
Make sure the spring power and closing speed are correct. If
adjustments are necessary, use 3/32 allen wrench provided
and refer to door diagram shown in
Fig. 9
. Turn
MAIN SPEED
& LATCH SPEED
screws clockwise to slow door speed,
counter-clockwise to increase speed. The installation of the
controller will make the
MAIN
and
LATCH SPEED
regulating
screws inaccessible.
NOTE:
Do not back regulating screws out of closer or an oil leak
will occur
Fig. 9
LATCH SPEED
MAIN SPEED
BACKCHECK
2.
BACKCHECK ADJUSTMENT:
Backcheck slows the door swing as it approaches full opening.
Adjust the backcheck setting only if necessary. Increase
backcheck strength by turning
BACKCHECK
screw clockwise
by quarter turns. Make sure backcheck adjustments conform to
ANSI A156.19 sections 4.2, 4.4, 4.5, and tables I & II.
DO NOT
USE AN ABRUPT BACKCHECK SETTING.
FOR 4640CS SERIES ONLY:
To adjust for additional closing
power at latch:
a. Remove forearm set screw and open door, separating rod
from forearm tube.
b.
Remove shoe screws and flip shoe 180° as shown in
Fig.
10
. Re-attach shoe to door.
c. Re-assemble arm, as in steps 3 & 4 on page 8.
d. Verify that closing force is no more than 15 lbs when
measured one inch from door edge to comply with ANSI
A156.19.
For 4640CS series only
Fig. 10
STANDARD
INSTALLATION
SHOE POSITIONED
FOR INCREASED
POWER AT LATCH
LOCATING CAUTION / AUTOMATIC DOOR DECAL
1. Locate one decal on each side of door, near latch area to meet
ANSI A156.19-2007 code requirements. Decal must be located
at 50” (+/- 12”) from the floor to the center line of the sign. The
decal location must be visible without interference from door
trim or auxiliary door hardware.
2. Clean the 6” x 6” area where decal is to be placed. Apply decal
by removing the backing and “rolling” it onto door. This will help
prevent air bubbles from being trapped under decal.
AUTOMATIC
DOOR
CAUTION