LCN 4600CS Скачать руководство пользователя страница 10

Page 10

SECTION 3

INSTALLATION & ADJUSTMENT

OF CONTROLLER BOARD

NOTE:

 Be sure electrical power source is disconnected.

1. 

MOUNT CONTROLLER TO OPERATOR ASSEMBLY:

 

Locate controller assembly in shipping carton. Position the 

controller as shown in 

Fig. 11

. Slide onto mounting plate 

assembly, guiding cut-outs in controller onto mounting pins as 

shown.

2. 

Once the front of controller is fitted onto pins, push entire 

controller into position, as shown in 

Fig. 12

. With controller in 

proper position, insert (1) 

unpainted 

#8 - 32 x 3/8” flat head 

screw into bottom of mounting plate, as shown.

Fig. 11

Fig. 12

NOTE:

 For adjustments to door closer regulating screws, 

controller must be removed. Do this by: Removing power to 

operator, unplugging the electrical connections, removing screw, 

tilting controller away from operator and disengaging controller 

from mounting pins. Follow steps 1 & 2 above to reattach.

WIRING CONNECTIONS:

1.  There will be 3 keyed wiring harness connectors shipped in the 

hardware box. The first is a ribbon cable connector. It should 

be fitted into receptacles on rear board assembly and the 

controller as shown in 

CONNECTION #1

 of 

Fig. 13

.

Fig. 13

CONNECTION #1

CONTROLLER

RIBBON CABLE

CONNECTION #2

120VAC POWER

CONNECTION #3

MOTOR / CLUTCH

2. 

The second connector is a 2 wire lead for the 120 VAC 

power and should be fitted firmly into into receptacles 

on rear board assembly and the controller as shown in 

CONNECTION #2 of Fig. 13.

3.  The third connector is for the motor / clutch. The connector 

should be fitted firmly into receptacle on the controller as 

shown in 

CONNECTION #3

 of 

Fig. 13

.

4.  Electrical power can now be safely supplied to the 4600CS 

series operator. The controller settings have been pre-set prior 

to shipment. Adjustment information is detailed on pages 15-

17. It will be necessary for the 4600CS series door operator to 

be functional while adjustments and settings are made. Trigger 

actuator device(s) and check to make sure that door opens 

freely. Arm assembly motion and door travel should not make 

contact or have interference with any object.

Содержание 4600CS

Страница 1: ...nt adjustment of a Door Opening Speed b Delay Trigger Time for Sequential Option c Door Opening Force d Electric Strike Delay Time e Hold Open Time f 90 Slow Down g Alternate Action Timeout h Safety S...

Страница 2: ...exceed 5 The 4642 accommodates reveals up to 4 Z x For reveal depths of 4 Z x 8 requires 4642 L Long Arm For reveal depths greater than 8 consult factory Maximum door weight is 225 lbs The 4600CS seri...

Страница 3: ...frame must be vertically level Conduit access holes in frame are for CONCEALED WIRING ONLY If using concealed wiring option see step 2 below FOR SURFACE WIRING proceed to step 3 2 Refer to correct tem...

Страница 4: ...P O R E W O P 0 9 R A I L I X U A D E D N E M M O C E R P O T S Y R E S O L C D N A R O O D D N A H T F E L E T I S O P P O D N A H T H G I R N W O H S S E I R E S S C 0 3 6 4 T E D I S L L U P D E T...

Страница 5: ...TO FRAME MUST CORRESPOND TO VOLTAGE OF OPERATOR 2 MAXIMUM BUTT SIZE IS 5 3 MINIMUM DOOR WIDTH IS 36 4 MAXIMUM STOP THICKNESS IS 5 8 5 MAXIMUM REVEAL DEPTH IS 4 UP TO 8 REVEALS WITH LONG ARM OPTION CON...

Страница 6: ...ch from door edge to comply with ANSI A156 19 TABLE 1 INTERIOR DOOR MAXIMUM DOOR WIDTH NUMBER OF TURNS 36 0 48 2 TURNS C W 54 7 TURNS C W TABLE 2 EXTERIOR DOOR MAXIMUM DOOR WIDTH NUMBER OF TURNS 36 2...

Страница 7: ...4 20 x 1 Z x machine screws or 2 No 14 x 2 Z x wood screws provided 3 Locate SHAFT EXTENSION LOCK WASHER SPACER ARM SHAFT SCREW in fastener box Fit arm and spacer onto shaft extension Place lock wash...

Страница 8: ...nd shaft extension Fit arm assembly over closer shaft so main arm is positioned at approx 90 to operator assembly and fasten with arm shaft screw as shown in Fig 7 above 2 Attach rod shoe assembly to...

Страница 9: ...rter turns Make sure backcheck adjustments conform to ANSI A156 19 sections 4 2 4 4 4 5 and tables I II DO NOT USE AN ABRUPT BACKCHECK SETTING FOR 4640CS SERIES ONLY To adjust for additional closing p...

Страница 10: ...wiring harness connectors shipped in the hardware box The first is a ribbon cable connector It should be fitted into receptacles on rear board assembly and the controller as shown in CONNECTION 1 of F...

Страница 11: ...11 N O 12 N C E S Relay Contacts 5 amp max 22 Common 23 N O 24 N C 12V DC 24V DC Negative 2 4 13 17 19 7 5 e v i t i s o P C D V 2 1 3 1 e v i t i s o P C D V 4 2 Note 1 Amp max load between 12V and...

Страница 12: ...SEQUENTIAL WIRING CONNECTIONS INDEPENDENT VESTIBULE SEQUENTIAL ACTUATOR SEQUENTIAL ACTUATOR VESTIBULE ACTUATOR VESTIBULE ACTUATOR ANY NORMALLY OPEN DRY CONTACT ACTUATOR ANY NORMALLY OPEN DRY CONTACT A...

Страница 13: ...NNECTIONS SIMULTANEOUS VESTIBULE SEQUENTIAL PAIR WIRING CONNECTIONS INDEPENDENT VESTIBULE PAIRS VESTIBULE ACTUATOR SEQUENTIAL ACTUATOR SEQUENTIAL ACTUATOR VESTIBULE ACTUATOR SEQUENTIAL ACTUATOR VESTIB...

Страница 14: ...SUPPLY EPT POWER TRANSFER EL DEVICE GROUND OUT 2 IN 2 OUT 1 IN 1 SC EARTH GROUND 120V NEUTRAL 120V HOT WIRING INFORMATION FOR ELECTRIC STRIKE MAG LOCK SYSTEM 24V DC 24V DC FOR ADDITIONAL WIRING INFORM...

Страница 15: ...oor speed and use of an auxiliary door stop will provide smoother operation 3 OPENING FORCE Adjusts amount of force the door exerts when opening 15 lbs max Normal adjustment is for door to open 90 or...

Страница 16: ...n timer starts after door encounters second restriction 5 E S DELAY Controls the time between activation signal and actual door movement Allows time for electric latching hardware to release before do...

Страница 17: ...t and display will show programmed state To change state press UP or DOWN button respectively Adjustment ON OFF Default ON To continue programming mode press mode button E S DELAY indicator will be li...

Страница 18: ...the next operator 4 Controller monitors the motor during opening cycle for door obstructions that exceed the present OPENING FORCE setting If an obstruction is encountered controller will pause openi...

Страница 19: ...MOTOR CLUTCH ASSY 20 CONDUIT COVER 155G DOOR DECAL When ordering replacement parts remember to specify Model 4630 or 4640 in front on the desired part Also specify Color Finish when required 4630 3038...

Страница 20: ...Allegion 2014 Printed in U S A 29268 Rev 01 14 e...

Страница 21: ...01 14 Notes 1 printed two sides 2 printed black 3 tolerance 13 4 printed in country may vary 5 drawings not to scale 6 printed saddle stitch booklet Title 4630CS 4640CS Series Instruction Manual Creat...

Отзывы: