Electrical Checkout

 

L

after completion of installation & wiring, and with the unit 

properly powered, perform the following steps:

LED

When 24V AC/DC power is applied, the LED on the scanner will 

flash on and off for 10 seconds, then turn off. The scanner LED will 

stay lit as long as any motion is detected. The scanner LED will 

remain lit for 15 seconds after motion has stopped, and then it turns 

off.

Scanner Sensitivity

Adjust the scanner sensitivity if required (Figure 4).

Door Hold Open Time

The door hold open time is controlled by the scanner, and it is set 

at 15 seconds. This time can be set at 30 seconds by setting switch 

3 to “On” (see Figure 4).

Hold Open Operation

To check the hold open operation, open the door beyond 80°. The 

door should remain in the hold open position. The door should 

release and close 15 seconds after there is no motion at the door.

Continuous Hold Open

For continuous hold open, press the switch once to put the unit in 

the continuous hold open mode. Press the switch again to activate 

the timed hold open mode. The door must be opened beyond 80° 

for the hold open function to take effect.

Electrical Data

4412 HSa Scanner activated Hold Open:

Voltage  24V AC/DC Nominal (+10% - 15%)

 

Standby Current   

0.010a

 

Hold Open Current 

0.120a

1

2

3

Cover Alignment Tab

Mask

Figure 4: To adjust Scanner Sensitivity

1.  Insert a small screwdriver on the side of the housing and gently 

pry the cover off.

2.  Keep mask and cover together as shown. 

 

Note: Cover alignment tab.

1

2

3

Cover Alignment Tab

Mask

3.  Set dip switch1 to ON to increase sensitivity.

1

2

3

Cover Alignment Tab

Mask

 

L

note: Leave switches 2 & 3 OFF.

4.  Snap  mask and cover onto scanner housing.

 

Note: Cover alignment tab fits into a notch on the bottom of the 

scanner housing.

1

2

3

Cover Alignment Tab

Mask

 

Figure 5

5.  Rotate scanner towards mounting plate, as shown in Figure 5 

(above).

Содержание 4412 HSA

Страница 1: ...anner Activated Hold Open 4412 HSA Installation Instructions Scanner Cover Packing Nut Spring Power Adjustment Main Arm Assembly Arm Shaft Screw Power Board Mounting Bracket for Surface Run Conduit Hole for Concealed Conduit Rod Shoe Assembly Arm Set Screw How To Tell Hand Of Door 68 N m 50 ft lbs Maximum Opening Torque Maximum Opening Torque LH RH 68 N m 50 ft lbs Customer Service 1 877 671 7011 ...

Страница 2: ... on the closer shaft 90 to the closer body and secure with the arm shaft screw 6 Track Setup Attach the rod shoe to the door per the template on page 5 with the screws provided 7 Set Screw Open the door partway insert the rod into the forearm then close the door With the main arm at a right angle 90 to the door insert the arm set screw and tighten securely 8 Spring Power Adjustment See Figure 1 fo...

Страница 3: ...T BLACK WIRES TO INPUT VOLTAGE LEADS POLARITY NOT IMPORTANT CONNECT GREEN WIRE TO EARTH GROUND CONNECT BLACK WIRES TO INPUT VOLTAGE LEADS POLARITY NOT IMPORTANT Figure 1 Spring Power Adjustment Closing Speed Regulation 1 2 3 Spring Adjustment Increase Force Decrease Force Backcheck Main Speed Latch Speed ...

Страница 4: ...d close 15 seconds after there is no motion at the door 5 Continuous Hold Open For continuous hold open press the switch once to put the unit in the continuous hold open mode Press the switch again to activate the timed hold open mode The door must be opened beyond 80 for the hold open function to take effect Electrical Data 4412 HSA Scanner Activated Hold Open Voltage 24V AC DC Nominal 10 15 Stan...

Страница 5: ...e door is hung on pivots locate the closer and shoe from the centerline of pivot if the door is hung on swing clear hinges consult the factory 6 Fllor or wall stops are recommended at maximum hold open 7 For additional information on recommended use of this unit consult the NFPA 72E pamphlet 8 Reinforcing per ANSI SDI 100 is recommended for hollow metal doors and frames Inch Z v C Z x B C v M 1Z 1...

Отзывы: