© Allegion 2014

Printed in U.S.A.

24771 Rev. 01/14-k

4040SE-DE: For 

B\,

” Step-down frames 

warNiNg

HaZarDOuS VOLTagE CaN SHOCK aND CauSE SEVErE iNJurY!

Disconnect the power before making any electrical connections or performing maintenance.

DOOR HOLDER SOLENOID DATA

24VAC - DC Nominal =10% - 15% @ .090 Amp. Max.

120 VAC - DC Nominal =10% - 15% @ .030 Amp Max.

4040 SE DE Up To 95° Hold Open

Auxiliary Stop Recommended

Templating for Left Hand Door

Optional

Wiring

Connections

Jamb

Line

Jamb

Line

Hinge Edge

of Door

Double

Egress Arm

Top of

Door

2¹¹⁄₁₆

Max.

1¹⁄₂ 

Min. for SE

³⁄₄

⁵⁄₈

⁵⁄₈

⁵⁄₈

⁷⁄₈

1

3

26¹⁄₄

21³⁄₄

4

2¹⁄₄

1

1¹⁄₄

 Hole for Electrical Connector if

Concealed Conduit Option Is Used

Templating for Right Hand Door

Optional

Wiring

Connections

Jamb Line

Jamb

Line

Hinge Edge

of Door

Top of

Door

Double

Egress Arm

2¹¹⁄₁₆

Max.

1¹⁄₂ 

Min. for SE

1¹⁄₄

 Hole for Electrical Connector if

Concealed Conduit Option Is Used

26¹⁄₄

21³⁄₄

4

1

1

2¹⁄₄

3

³⁄₄

⁵⁄₈

⁵⁄₈

⁵⁄₈

⁷⁄₈

  

Dim.

Reveal

7M\,

2ZZ\zn

7C\,

2

6C\v

1Z\x

6Z\x

1

DOOR HOLDER SOLENOID DATA

24VAC - DC Nominal =10% - 15% @ .090 Amp. Max.

120 VAC - DC Nominal =10% - 15% @ .030 Amp Max.

4040 SE DE Up To 95° Hold Open

Auxiliary Stop Recommended

Templating for Left Hand Door

Optional

Wiring

Connections

Jamb

Line

Jamb

Line

Hinge Edge

of Door

Double

Egress Arm

Top of

Door

2¹¹⁄₁₆

Max.

1¹⁄₂ 

Min. for SE

³⁄₄

⁵⁄₈

⁵⁄₈

⁵⁄₈

⁷⁄₈

1

3

26¹⁄₄

21³⁄₄

4

2¹⁄₄

1

1¹⁄₄

 Hole for Electrical Connector if

Concealed Conduit Option Is Used

Templating for Right Hand Door

Optional

Wiring

Connections

Jamb Line

Jamb

Line

Hinge Edge

of Door

Top of

Door

Double

Egress Arm

2¹¹⁄₁₆

Max.

1¹⁄₂ 

Min. for SE

1¹⁄₄

 Hole for Electrical Connector if

Concealed Conduit Option Is Used

26¹⁄₄

21³⁄₄

4

1

1

2¹⁄₄

3

³⁄₄

⁵⁄₈

⁵⁄₈

⁵⁄₈

⁷⁄₈

  

Dim.

Reveal

7M\,

2ZZ\zn

7C\,

2

6C\v

1Z\x

6Z\x

1

Notes:

1.  The voltage supplied must match the voltage shown on the Sentronic label.

2.  If the door is hung on pivots or swing clear hinges, consult the factory.

3.  Floor or wall stops must be used.

4.  For 7

Z\v

” or less double egress frames, the reveal should not exceed 

2ZZ\zn

”.

5.  The 

Z\,

” door-to-Soffit clearance is required.

6.  Reinforcing per ANSI/SDI-100 is recommended for hollow metal doors and frames.

7.  The maximum butt hinge size is 5” x 5”. 

Inch

Z\,

Z\v

M\,

ZB\zn

1

1Z\,

1Z\v

1Z\x

1C\v

2

2Z\v

2ZZ|zn

2M\,

3

4

5

6Z\x

6C\v

7Z\v

7C\,

7M\,

21C\v

26Z\v

M.M.

3

6

22

24

25

29

32

38

44

51

57

68

73

76

102

127

165

171

184

187

200

552

667

Customer Service

1-877-671-7011

www.allegion.com/us