Altitude window 

 
Shortly after take-off, the main window will automatically display altitude readings 
The displayed altitude increments (feet / meter) depend on the current altitude 
 
 
 

 

 

 

 

0 - 990 

Altitude display:  Normal 

Increments of 10 feet / 5 meters 

 

1.000 – 9.990 

Altitude display: 10s  

Increments of 10 feet / 10 meters 

 

 

10.000 and above 

Altitude display: 100s 

Increments of 100 feet / 100 meters 

 

 
Logbook and Jump Info / Settings 

 
Display examples, after performing ACCESS, are shown in the separate sections 
 
  

Jump Profile 

 
The jump profile window is used when playing back the last jump 
 
 

1

 

Time display 

2

 

Altitude display / Speed display 

3

 

Feet/meter indicator 

 
 

 

 

Battery Indicator 

 
The battery indicator shows the current battery status 
 

 

Full capacity: 

Two black bars are shown inside the battery symbol 

 

Half capacity: 

One black bar is shown inside the battery symbol 

 

Low capacity: 

The battery symbol is empty. The batteries must be replaced as soon as possible 

 

Empty: 

The battery symbol is flashing. Do not continue jumping. Replace batteries immediately 

 
Warning: 

Do not perform night jumps, or jumps in sub-zero temperatures (Celsius) when the battery symbol shows low capacity 

 
 

 

Содержание ALFA

Страница 1: ...means of maintaining altitude awareness Use the ALFA at your own risk Altimeters may give erroneous readings if you are tumbling or the altimeter is in a burble wake Chest mount altimeters are more v...

Страница 2: ...p Counter 8 Total Jumps 8 Exit Altitude 8 Opening Altitude 8 Freefall Time 8 Average Freefall Speed 9 Maximum Freefall Speed 9 Altitude Profile Last Jump 9 Speed Profile Last Jump 9 Exit Logbook and J...

Страница 3: ...vation User selection of feet meter and mph kmh Stores up to 10 min of data from last jump Log book stores up to 200 jumps including o Date time o Exit opening altitudes o Free fall time o Max average...

Страница 4: ...in the separate sections Jump Profile The jump profile window is used when playing back the last jump 1 Time display 2 Altitude display Speed display 3 Feet meter indicator Battery Indicator The batte...

Страница 5: ...de Profile Last Jump Speed Profile Last Jump Year Date Time Jump Counter Units Altitude Units Speed Dive Type Delete Last Jump Delete Logbook Turn OFF PERFORMING ACCESS In order to access each of the...

Страница 6: ...absolute air pressure for the landing zone Select the mbar value registered calculated for the landing zone Press and hold for 5 seconds Press to increase altitude Mbar Press to reduce altitude Mbar P...

Страница 7: ...ity can be set in 10 steps after backlight is turned ON Step 1 lowest intensity step 10 highest intensity Press to increase intensity Press to decrease intensity ALFA stores the last setting Press to...

Страница 8: ...e information Press to select next jump Press to select previous jump Date and time for the selected jump is shown at the top of the screen Press to continue Exit Altitude Displays exit altitude for s...

Страница 9: ...at a given time for the last jump Press to scroll forward in time seconds Press to scroll backwards in time seconds Holding down either will fast scroll Time is shown at the top of the screen Press to...

Страница 10: ...the top of the screen Press to continue Date Sets current date Press to select next date Press to select previous date To change month Scroll DAY until reaching 31 or 1 then ALFA will scroll MONTH up...

Страница 11: ...s Press or to switch between Dive Types Press to continue Delete Last Jump Deletes the last jump in the logbook To avoid unintentional deletions the counter at the top of the screen must be set to 5 P...

Страница 12: ...screen must be set to 5 Press and to match counter to 5 Press to accept deletion of last jump Warning If the counter is set at 5 cannot be used to scroll through settings and will turn ALFA off Press...

Страница 13: ...ng Altitude Offset the ALFA enters Flight Mode and will retain any offset for 14 hours if no jump is made After 14 hours the unit calibrates itself to the field elevation where it is located To exit F...

Страница 14: ...ed into water allow the unit and air filter to dry in a warm place for 48 hours The air filter must be replaced if jumping is to be resumed immediately or if the air filter is suspected to be contamin...

Страница 15: ...Minimum freefall time for logbook generation in Student mode 3 seconds Maximum logging altitude Normal mode 30 000 ft 9 150 m Maximum logging altitude Student mode 40 000 ft 12 200 m Maximum Profile s...

Страница 16: ...pt The warranty becomes void if damage is caused by external circumstances or if the unit has been serviced or repaired by third parties unauthorized by our national agents or LB ALTIMETERS All furthe...

Страница 17: ...de Offset IR Mode Backlight ON OFF Turn ALFA ON ALFA is OFF ALFA is ON Performing ACCESS to Logbook and Jump Info hold button down Press and release Press Release Logbook and Jump Info window Performi...

Страница 18: ...Freefall Speed Freefall Time Altitude Profile Last Jump Opening Altitude ACCESS LOGBOOK and JUMP INFO Press to rotate selection Press or for information ACCESS to Settings Year Date Time Jump Counter...

Отзывы: