LB Altimeters ALFA Скачать руководство пользователя страница 11

ALFA  -  Rev. 1.15 

Page 11 of 18 

 

Units - Altitude 

 
Sets altitude display in either feet or meters 

 
 

Press 

 or 

 to switch units 

 
 

Press 

 to continue 

 

 

 

Units - Speed 

 
Sets altitude display in either miles/hour or kilometers/hour 

 
 

Press 

 or 

 to switch units 

 
 

Press 

 to continue 

 

 

 

Dive Type  

 
Sets the current dive type used for logging data: 
 

0: 

Standard 

 
1: 

Slow 

 

The exit and deployment parameters are designed to fit very slow fall rates, such as wingsuiting 

 

 

 

Freefall detection is very sensitive, and may register jumps if the airplane descends 

 
2: 

Student  

The descent rate parameters are changed to fit very short free falls (2 seconds) 

 
 

Press 

 or 

 to switch between Dive Types 

 
 

Press 

 to continue 

 

 

 

Delete Last Jump 

 
Deletes the last jump in the logbook 
 
To avoid unintentional deletions, the counter at the top of the screen must be set to ‘5’ 
 

 

Press 

 and 

 to match counter to ‘5’ 

Press 

 to accept deletion of last jump 

 
 

WARNING:

 

If the counter is set at ‘5’, 

 cannot be used to scroll through settings and will delete last 

jump. Once deleted, the jump data is lost 

 

Press 

 to continue 

 

 

 

Delete Log Book 

 
Deletes the entire logbook  
 
To avoid unintentional deletions, the counter at the top of the screen must be set to ‘19’ 

 

Press 

 and 

 to match counter to ‘19’ 

Press 

 to accept deletion of last jump 

 
 

WARNING:

 

If the counter is set at ‘19’, 

 cannot be used to scroll through settings and will delete 

the entire logbook. Once deleted, the logbook data is lost 

 

Press 

 to continue 

 

 

 

 

 

Содержание ALFA

Страница 1: ...means of maintaining altitude awareness Use the ALFA at your own risk Altimeters may give erroneous readings if you are tumbling or the altimeter is in a burble wake Chest mount altimeters are more v...

Страница 2: ...p Counter 8 Total Jumps 8 Exit Altitude 8 Opening Altitude 8 Freefall Time 8 Average Freefall Speed 9 Maximum Freefall Speed 9 Altitude Profile Last Jump 9 Speed Profile Last Jump 9 Exit Logbook and J...

Страница 3: ...vation User selection of feet meter and mph kmh Stores up to 10 min of data from last jump Log book stores up to 200 jumps including o Date time o Exit opening altitudes o Free fall time o Max average...

Страница 4: ...in the separate sections Jump Profile The jump profile window is used when playing back the last jump 1 Time display 2 Altitude display Speed display 3 Feet meter indicator Battery Indicator The batte...

Страница 5: ...de Profile Last Jump Speed Profile Last Jump Year Date Time Jump Counter Units Altitude Units Speed Dive Type Delete Last Jump Delete Logbook Turn OFF PERFORMING ACCESS In order to access each of the...

Страница 6: ...absolute air pressure for the landing zone Select the mbar value registered calculated for the landing zone Press and hold for 5 seconds Press to increase altitude Mbar Press to reduce altitude Mbar P...

Страница 7: ...ity can be set in 10 steps after backlight is turned ON Step 1 lowest intensity step 10 highest intensity Press to increase intensity Press to decrease intensity ALFA stores the last setting Press to...

Страница 8: ...e information Press to select next jump Press to select previous jump Date and time for the selected jump is shown at the top of the screen Press to continue Exit Altitude Displays exit altitude for s...

Страница 9: ...at a given time for the last jump Press to scroll forward in time seconds Press to scroll backwards in time seconds Holding down either will fast scroll Time is shown at the top of the screen Press to...

Страница 10: ...the top of the screen Press to continue Date Sets current date Press to select next date Press to select previous date To change month Scroll DAY until reaching 31 or 1 then ALFA will scroll MONTH up...

Страница 11: ...s Press or to switch between Dive Types Press to continue Delete Last Jump Deletes the last jump in the logbook To avoid unintentional deletions the counter at the top of the screen must be set to 5 P...

Страница 12: ...screen must be set to 5 Press and to match counter to 5 Press to accept deletion of last jump Warning If the counter is set at 5 cannot be used to scroll through settings and will turn ALFA off Press...

Страница 13: ...ng Altitude Offset the ALFA enters Flight Mode and will retain any offset for 14 hours if no jump is made After 14 hours the unit calibrates itself to the field elevation where it is located To exit F...

Страница 14: ...ed into water allow the unit and air filter to dry in a warm place for 48 hours The air filter must be replaced if jumping is to be resumed immediately or if the air filter is suspected to be contamin...

Страница 15: ...Minimum freefall time for logbook generation in Student mode 3 seconds Maximum logging altitude Normal mode 30 000 ft 9 150 m Maximum logging altitude Student mode 40 000 ft 12 200 m Maximum Profile s...

Страница 16: ...pt The warranty becomes void if damage is caused by external circumstances or if the unit has been serviced or repaired by third parties unauthorized by our national agents or LB ALTIMETERS All furthe...

Страница 17: ...de Offset IR Mode Backlight ON OFF Turn ALFA ON ALFA is OFF ALFA is ON Performing ACCESS to Logbook and Jump Info hold button down Press and release Press Release Logbook and Jump Info window Performi...

Страница 18: ...Freefall Speed Freefall Time Altitude Profile Last Jump Opening Altitude ACCESS LOGBOOK and JUMP INFO Press to rotate selection Press or for information ACCESS to Settings Year Date Time Jump Counter...

Отзывы: