Sentinel Press Brake Guarding System Operation Manual
LS-CS-M-066
Page 28
Original Language Version: 1.06
Released:
03/07/2019
M ENU
M OD E
SELECT
TOOL
SETU P
SET
INFO
ACTI ON
RELEASE FOOT PEDAL
Sensors blocked
4220
A
B
STATUS
Figure 6-6: Laser B Obstructed by the Material
Release the foot pedal. The Status screen changes to a red background, and prompts the
operator to
CONFIRM MUTE POINT - PRESS SET BUTTON
, as shown in
. (If an
external mute lamp has been installed, the lamp will light).
M ENU
M OD E
SELECT
TOOL
SETU P
SET
INFO
ACTI ON
PRESS SET BU TTON
CONFIRM MUTE POI NT
0000
A
B
STATUS
Figure 6-7: Confirm Mute Point Screen
To confirm the detected position as the mute point, press the
SET
button. The Status screen
will change back to black, and The
SET
button label changes to
MUTE RESET
as shown in
. (if an external mute lamp has been installed it will turn off).
The Status screen now displays the message
NORMAL MODE Ready to bend
.
6.4
Resetting the Mute Point
Any time the tools or the material thickness is changed, the mute point must be reset. When
the machine is at TDC press the
MUTE RESET
button. If the machine is not at TDC, the
message
Open tools to enable button function
will be displayed in the Status window.
Note:
Do not press the foot pedal while the
MUTE RESET
label is flashing. If the foot pedal
is pressed, the mute reset operation is cancelled.