Sentinel Press Brake Guarding System Operation Manual
LS-CS-M-066
Page 29
Original Language Version: 1.06
Released:
03/07/2019
When pressed and released, the
MUTE RESET
button will flash three times while the mute
point is cleared. During this time the message
Mute point resetting
–
PRESS FOOT PEDAL TO
CANCEL
is displayed. After the reset is complete, the screen again appears as in
prompting the operator to
SET MUTE POINT
–
PRESS FOOT PEDAL.
M ENU
M OD E
SELECT
TOOL
SETU P
M UTE
RESET
INFO
ACTI ON
NORM AL MODE
Ready to bend
0000
A
B
STATUS
Figure 6-8: Mute Set, Ready to Bend
6.5
Selecting Tray/Box Modes
To change the optical protection mode the Sentinel panel must be in the Mode Select screen.
From the Main screen press the
MODE SELECT
button, and the screen will change to the
Mode Select screen.
When changing modes the tools must be open with the block laser above the mute point and
clear of any obstructions. Also, the system should be in Normal mode (the default start-up
mode). If these conditions are not met, the Status window will display the message
Open tools
to enable button function
.
FIELD
MUTED
GUARD
MODE
MUTE
STOP
BACK
GAUGE
ACTION
NORMAL MODE
Ready to bend
0000
STATUS
A
B
Figure 6-9: Mode Select Screen
•
Press the
GUARD MODE
button to enter Tray Mode.
•
Press the
GUARD MODE
button again to enter Tray 2 mode.
•
Press the
GUARD MODE
button again to return to Normal mode.