background image

17 

   For HELP, call La-Z-Boy

®

 Spas at 1.800.465.2933. 

Electrical Specifications 

120V to 240 V Conversion Continued 

Step 3. 

Turn Dipswitch #10 off (down). To run 
at 240V, dipswitch #7 should be in the 
on position. 

Your 240V wiring should look like 
this. 
 
See Wiring Diagram on page 18 for 
further information. 
 
If wiring appears differently,  
DO NOT power your spa! Consult a 
certified electrician.

 

To run at 120V, dip switches #7 & 10 are the only ones that should be in the ON position. Adjusting any 
other dip switches will render the spa inoperable and may cause permanent damage. This also voids all 
warranties.

 

PLEASE CHECK YOUR LOCAL BUILDING CODES AND ONLY USE A CERTIFIED ELECTRICIAN 
TO INSTALL ANY ELECTRICAL COMPONENTS TO YOUR SPA. 

Содержание 2012 Seduce

Страница 1: ...For HELP call La Z Boy Spas at 1 800 465 2933 2012 OWNER S MANUAL Seduce La Z Boy Spas Sales Marketing Division 4411 Bee Ridge Road 299 Sarasota Florida 34233 1 800 465 2933 www lazboyspas com 3180220...

Страница 2: ...a Z Boy Spas La Z Boy is a registered trademark of La Z Boy Incorporated and is used under license to 2217044 Ontario Inc La Z Boy Spas may make product modifications and enhancements Specifications m...

Страница 3: ...uld consult a physician before using spa or hot tub Warning People with infectious diseases should not use a spa or hot tub Warning To avoid injury exercise care when entering or exiting the spa or ho...

Страница 4: ...ion Maintain water chemistry in accordance with the manufacturer s instructions Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temp...

Страница 5: ...ite immediately upon completion of spa installation Important It is extremely important that this sign be permanently placed in clear view of persons using the spa hot tub Occasional spa hot tub users...

Страница 6: ...___________________________________ Address __________________________________________________________________ Telephone __________________________________________________________________ Date Deliver...

Страница 7: ...7 For HELP call La Z Boy Spas at 1 800 465 2933...

Страница 8: ...8 For HELP call La Z Boy Spas at 1 800 465 2933...

Страница 9: ...damages caused by improper installation or use of spa hot tub improper or otherwise Notes _______________________________________________________________ _____________________________________________...

Страница 10: ...0 465 2933 Model Overview Seduce 120V Operation Dimensions 84 L x 84 W x 35 D Seats 5 Water Jets 30 Capacity 251 USG 950L Dry Weight 400 Lbs 182 kg Filled Weight 2500 Lbs 1134 kg Electrical 120VAC 15A...

Страница 11: ...800 465 2933 Model Overview Seduce 240v Operation Dimensions 84 L x 84 W x 35 D Seats 5 Water Jets 30 Capacity 251 USG 950L Dry Weight 400 Lbs 182 kg Filled Weight 2500 Lbs 1134 kg Electrical 240 VAC...

Страница 12: ...m solid flat surface designed to properly support its weight For external installations a 4 inch 10 cm thick cement pad suffices See page 14 for conduit entry locations for your model spa 5 For intern...

Страница 13: ...13 For HELP call La Z Boy Spas at 1 800 465 2933 Location and Installation Figure 1 Clearances and Support...

Страница 14: ...ference Points Model Dimension A Dimension B Seduce 30 76 cm 8 20 cm Table 1 Conduit Entry Location Dimensions 10 Consider positioning your spa hot tub out of or adequately protecting it from the wind...

Страница 15: ...se and periodically when the spa is powered To test the GFCI plug version follow these instructions Spa should already be plugged in and operational 1 Press the TEST button on the GFCI The GFCI will t...

Страница 16: ...y of the spa owner The steps to converting your spa from 120V to 240V operation are shown below and must be completed by a licensed electrician Power supply installation must include a properly rated...

Страница 17: ...m on page 18 for further information If wiring appears differently DO NOT power your spa Consult a certified electrician To run at 120V dip switches 7 10 are the only ones that should be in the ON pos...

Страница 18: ...er appliances or lights sharing the power GFCI and Wiring Requirements Use copper wire with THHN insulation Do not use aluminum wire Use the table on this page to determine your GFCI and wiring requir...

Страница 19: ...Means for disconnection must be used with fixed wiring configurations in accordance with local wiring rules IMPORTANT To allow the GFCI to function properly connect the white Neutral wire from the sp...

Страница 20: ...rly sized 50 AMP GFCI Circuit Breaker 240V Operation Only Installation including selection of conductor size and type must be performed by a qualified electrician in accordance with the National Elect...

Страница 21: ...cal dealer for assistance For best results read each step in its entirety before proceeding CAUTION Running the spa hot tub pump dry without water running through it can cause IMMEDIATE damage and wil...

Страница 22: ...pumps are tight 7 Clean out any foreign debris from within the service access area or inside of the spa hot tub itself 8 With the drain open and filters removed thoroughly rinse out the spa hot tub wi...

Страница 23: ...f the hose point the pre filter into a suitable drain turn on the water and allow any sediment to be flushed down the drain Once the water stream runs clear turn off the hose 4 Put the pre filter if e...

Страница 24: ...Ground Fault Circuit Interrupter GFCI breaker by pushing the small button This should automatically trip the spa hot tub circuit breaker Only if pushing this button successfully trips this circuit br...

Страница 25: ...speed pump Check to ensure water is coming from some of the jets If the water is not flowing out open the air bleed valve slightly to release trapped air Close the valve when the pump pushes water out...

Страница 26: ...ter with a good quality test kit Maintain a total alkalinity level of 80 to 120 ppm Total alkalinity is the measure of alkaline buffers in your water These buffers protect the water against sudden cha...

Страница 27: ...Chlorine Bromine Once your hardness level is proper it is imperative that you do not use the spa hot tub until there is a minimum reading of chlorine or bromine in the water Maintain a chlorine or bro...

Страница 28: ...e following table summarizes the desired water quality properties your spa hot tub should have Test Desired Value Total Alkalinity 80 to 120 ppm mg L pH 7 2 to 7 8 Hardness 200 to 400 ppm mg L Bromine...

Страница 29: ...most reliable choice in the harshest of climates Figure 11 Topside Control Panel Temp Control 80 F 104 F 26 C 40 C The last measured water temperature is constantly displayed The water temperature di...

Страница 30: ...t and will alternate with water temp when the pump is running Pump Press Pump to turn pump on or off and to shift between low and high speeds The low speed will turn off after 4 hours High speed will...

Страница 31: ...Feature Callouts 1 Lock down tab 2 Double stitched seams 3 Marine grade cover material 4 Edge overlap material 5 Grip handle 6 Aluminum channel 7 Heat sealed insulation 8 Chemical resistant vapor barr...

Страница 32: ...R green or brown water Your source water most likely has dissolved heavy metals When this is the case use a respected brand of demineralizer found at any local pool spa store Using a pre filter can re...

Страница 33: ...vice technician may assess reasonable travel charges during on site repairs What Happens when my Guarantee Expires Your local dealer will continue to provide service for your spa hot tub after your gu...

Страница 34: ...3 months depending on usage Every other time you drain and refill you should also replace the filters and wipe down the spa see page 43 What is the insulation made of The La Z Boy Spas Seduce model i...

Страница 35: ...aking Loosen the discharge union on the top of the pump until you hear the trapped air escape or water drips out in a continuous stream Turn on pump to make sure that there are no leaks Put the access...

Страница 36: ...Pump not running in constant filtration mode Temperature limit reached This is normal When the water temperature is 2 F over the set point and warmer than 95 F the pump automatically turns OFF in cons...

Страница 37: ...cuit breakers on GFCI panel and main circuit breaker panel Nothing works Breaker has tripped Check and reset breaker If problem persists check for loose electrical connections Check for Neutral wiring...

Страница 38: ...pside control panel High ambient temperature Remove the cover from the spa Water will not heat Thermostat is set too low Check and reset to desired temperature Air open Close air control valve Dirty f...

Страница 39: ...May appear temporarily in an overheat condition Spa is shut down The sensor that is plugged into the Sensor B jack is not working If the problem persists contact your dealer or service organization M...

Страница 40: ...ays on third occur rence of message Spa is shut down Follow action required for message Spa will not automatically reset Press any button to reset manually Ice Potential freeze condition detected No a...

Страница 41: ...d the following suggestions 2 Don t drag your cover on the ground wearing of the vinyl could easily develop into a tear 3 The insulating foam in your cover is not designed to hold the weight of a pers...

Страница 42: ...5 in reverse order to close the drain prior to refilling 8 Attach the garden hose to a thoroughly flushed pre filter not included rinsed of all residual sediment and refill your spa hot tub through t...

Страница 43: ...ht assembly counterclockwise turn to remove the light from its holder and clean in this same manner Surface The surface of your spa hot tub should be cleaned with a high quality all purpose cleaner an...

Страница 44: ...weather you should winterize your spa hot tub to avoid accidental freezing due to a power or equipment failure We highly recommend that you have a spa hot tub professional winterize and restart your...

Страница 45: ...ectrical component that keeps water moving throughout the entire circulation system Sanitizer A water additive that works with your Ozonator to help remove harmful elements in your spa water Spa Pack...

Страница 46: ...______________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________...

Отзывы: