Layher 3201 Скачать руководство пользователя страница 4

4

Assembly 

Layher Uni Light Tower

Dismantling 

To remove the different parts open the snap-on 

claws by depressing the locking clips. The red claws 

of the decks enable a single person to assemble or 

dismantle them easily; open them at one end and 

rest the base of the clips on the rung. Now open the 

opposite clips and remove the deck.
Dismantling is carried out in the reverse order of 

assembly. 

Remove the diagonal braces 

6

 and bracing 

elements only after having taken down the 

ladder frames 

1

 situated above. 

During assembly and dismantling, system decks or scaffold planks according to DIN 4420-3 (minimum measurement: 28 x 4.5 x 220 cm long) must be built in as 

auxiliary decks at maximum height intervals of 2.0 m. These auxiliary decks, providing a safe footing for assembly and dismantling, are removed after the erection. 

Each platform must be completely boarded. 

Components 

1   

 

Ladder frame 75/8      1297.008

ung

 

 

 

1a   Ladder frame 75/4    1297.004

Riefelung

 

  

2      Access deck 

1242.180

1.8 m

3      Deck 

1241.180

1.8 m

4      Guardrail 

1205.180

1.8 m

5      Double

guardrail

1.8 m

1206.180

6      Diagonale  

   1208.180

2.5 m

8      Mobile beam 

   1214.180

1.8 m

10    End toe board   1238.075

0.75 m

12     Ballast (10 kg)    1249.000

13     Spring clip 

   1250.000

16      Base ledger 

  1211.180

1.8 m

14      Uni- 

1275.110

distance tube 

1.1 m 

    

11      Toe board 

1239.180

with claw

1.8 m

15     

 

Special double coupler,

rigid 

19 mm WS 

  

1269.019

22 mm WS 

  

1269.022

7      Horizontal

brace 

1.95 m

 

1209.180

A

6

  

Operating the castors

During assembly and while working, the castors 

9

 

must be kept locked by pressing down the brake 

lever labelled STOP.

When the brake is locked, the lever labelled STOP 

is in the down position. For movement, the castors 

are unlocked by pushing the other lever down.

Wall support 

under load

For work performed on a load-bearing wall,  

ballasting can be reduced in accordance with 

the ballasting table (see page 5). In this case, 

wall supports must be installed on both sides of 

the tower. Use a Uni-distance-tube 

14

 and fix it 

to the ladder frame 

1

1a

 with the couplers 

15

The mobile beams are to be mounted so that the 

extension arms project from the side opposite to the 

wall. The wall supports must be attached at the 

height of the top working platform or at most 1 m 

below that.

14

  

15

 

 

15

  

14

  

15

  

15

 

 

2

 

 

side view

14

  

15

  

15

  

1

  

1a

 

 

8

  

8

  

Top view

9      Castor 150,

 

  

1308.150

Plastic wheel,

4 kN 

with single action 

brake device 

Bolt

   

  

1203.060

M 12 x 60 with nut

9

  

8

  

330 

Õ

Tighten 

bolt

M 12 x 60 

STOP