2
Tower Types
Layher Uni Light Tower
Tower Models
3201– 3207
Tower Model
3201
3202
3203
3204
3205
3206
3207
Working height (m)
3.15
4.3
5.3
6.3
7.3
8.3
9.3
Scaffold height (m)
2.44
3.55
4.55
5.55
6.55
7.55
8.55
Platform height (m)
1.15
2.3
3.3
4.3
5.3
6.3
7.3
Weight (kg)
54.3
118.7
127.1
148.9
190.6
208.3
222.7
Assembly
A
1
Pay attention to the General Assembly and Usage Instructions on page 6. The examples shown of the tower models 3201– 3207 are designed for use indoors
and outdoors. Pay attention to the parts list and ballasting table on page 5.
Insert the castors
9
into the ladder frames
1
and
secure against falling out by fastening the bolts M
12x60 and self-securing nuts through the holes pro-
vided. Connect and brace both ladder frames
1
with
two double guardrails
5
. Clip the access deck
2
onto
the 4th rung from the bottom. The snap-on claws of
all parts are to be locked onto the ladder frames
1
from above.
A three-part side guard must be attached when this
is required by the regulations applying for the job to
be performed.
In order to remove the different parts, depress the
locking clips of the snap-on claws. The red claws
of the deck enable a single person to assemble or
dismantle them easily; open them at one end and
rest the base of the clips on the rung. Now open
the opposite clips and remove the deck.
A
2
Tower Model 3201
Drawing 1
For outdoor use observe height limits!