© 2013, Lavorwash
13
Oil Fired Radiant Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE
BURNING, CONNECTED TO A POWER SOURCE
OR WHILE CONNECTED TO A FUEL SOURCE.
© 2013, BE Pressure Supply Pty Ltd
Kerosene Forced Air Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE OR WHILE
CONNECTED TO A FUEL SOURCE.
12
7URXEOHVKRRWLQJ*XLGH
Problem
Possible Cause
Solution
Heater Ignites, but main PCB shuts
off after a short period of time.
/DPSÀLFNHUVDQG/('GLVSOD\
shows “E1”.
1. Incorrect pump pressure.
2.
'LUW\LQSXWRXWSXWRUOLQW¿OWHU
'LUW\IXHO¿OWHU
4. Nozzle is dirty.
5. Photocell lens is dirty.
6. Photocell not installed properly.
7. Photocell is defective.
8. Improper electrical connection
between main PCB and photocell.
1. Adjust pump pressure.
2.
&OHDQUHSODFHDLURUOLQW¿OWHU
&OHDQUHSODFHIXHO¿OWHU
4. Clean / replace Nozzle.
5. Clean / replace photocell.
6. Adjust photocell position
7. Replace photocell
8. Check wiring connections
(see wiring diagrams on page 11).
Heater will not operate or motor
runs for a short time.
/DPSÀLFNHUVDQG/('GLVSOD\
shows “E1”.
1. No kerosene in the fuel tank.
2. Incorrect pump pressure.
Corroded spark plug or incorrect
plug gap.
4.
'LUW\IXHO¿OWHU
5. Dirty nozzle.
6. Moisture in fuel tank.
7. Improper electrical connection
between transformer and circuit
board.
8. Ignitor wire not connected to spark
plug.
9. Defective ignitor.
1. Fill tank with fresh kerosene.
2. Adjust pump pressure.
Clean / replace spark plug.
4.
&OHDQUHSODFHIXHO¿OWHU
5. Clean / replace nozzle.
6. Rinse fuel tank with clean, fresh
kerosene.
7. Inspect all electrical connections.
(See wiring diagrams on page 11.)
8. Re-attach ignitor wire to spark plug.
9. Replace ignitor.
Fan does not operate when heater
is plugged in and power switch is
in the “ON” position. The lamp is
ÀLFNHULQJRUDQG/('GLVSOD\VKRZV
“E1” or “E2”.
1. Thermostat is set too low.
2. Broken electrical connection
between main PCB and motor.
1. Rotate thermostat to a higher
setting
2. Inspect all electrical connections
(see wiring diagrams on page 11).
/DPSLVÀLFNHULQJDQG/('GLVSOD\
VKRZV³(´
1. Thermostat switch has failed.
1. Replace thermostat switch (see
Wiring diagrams on page 11).
Poor combustion and / or excess
soot production.
1.
'LUW\LQSXWRXWSXWRUOLQW¿OWHU
2.
'LUW\IXHO¿OWHU
Poor quality of fuel.
4. PSI is too high or too low.
1.
&OHDQUHSODFHDLURUOLQW¿OWHU
2.
&OHDQUHSODFHIXHO¿OWHU
Flush fuel tank and refuel heater.
4. Use proper pressure.
Heater does not turn on and the
lamp is not lit.
1. Temperature limit sensor has
overheated.
2. No electrical power.
Fuse is blown.
4. Improper electrical connection
between temperature limit sensor
and circuit board.
1. Push power switch to “OFF and
allow heater to cool for 10 minutes.
Restart heater.
2. Check power cords for proper
connection and test the power
supply.
Check / replace the fuse.
4. Inspect all electrical connections
(see wiring diagrams on page 11).