background image

© 2013, Lavorwash

13

Oil Fired Radiant Heater User’s Manual

NEVER LEAVE HEATER UNATTENDED WHILE 

BURNING, CONNECTED TO A POWER SOURCE 

OR WHILE CONNECTED TO A FUEL SOURCE.

© 2013, BE Pressure Supply Pty Ltd

Kerosene Forced Air Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED 

WHILE BURNING, CONNECTED TO A 

POWER SOURCE OR WHILE 

CONNECTED TO A FUEL SOURCE.

12

7URXEOHVKRRWLQJ*XLGH

Problem

Possible Cause

Solution

Heater Ignites, but main PCB shuts 

off after a short period of time. 

/DPSÀLFNHUVDQG/('GLVSOD\

shows “E1”.

1.  Incorrect pump pressure.

2.

'LUW\LQSXWRXWSXWRUOLQW¿OWHU

 'LUW\IXHO¿OWHU

4.  Nozzle is dirty.

5.  Photocell lens is dirty.

6.  Photocell not installed properly.

7.  Photocell is defective.

8.  Improper electrical connection 

between main PCB and photocell.

1.  Adjust pump pressure.

2.

&OHDQUHSODFHDLURUOLQW¿OWHU

 &OHDQUHSODFHIXHO¿OWHU

4.  Clean / replace Nozzle.

5.  Clean / replace photocell.

6.  Adjust photocell position

7.  Replace photocell

8.  Check wiring connections  

(see wiring diagrams on page 11).

Heater will not operate or motor 

runs for a short time.

/DPSÀLFNHUVDQG/('GLVSOD\

shows “E1”.

1.  No kerosene in the fuel tank.

2.  Incorrect pump pressure.

Corroded spark plug or incorrect 

plug gap.

4.

'LUW\IXHO¿OWHU

5.  Dirty nozzle.

6.  Moisture in fuel tank. 

7.  Improper electrical connection 

between transformer and circuit 

board.

8.  Ignitor wire not connected to spark 

plug.

9.  Defective ignitor. 

1.  Fill tank with fresh kerosene.

2.  Adjust pump pressure.

Clean / replace spark plug. 

4.

&OHDQUHSODFHIXHO¿OWHU

5.  Clean / replace nozzle.

6.  Rinse fuel tank with clean, fresh 

kerosene.

7.  Inspect all electrical connections. 

(See wiring diagrams on page 11.) 

8.  Re-attach ignitor wire to spark plug. 

9.  Replace ignitor.  

Fan does not operate when heater 

is plugged in and power switch is 

in the “ON” position. The lamp is 

ÀLFNHULQJRUDQG/('GLVSOD\VKRZV

“E1” or “E2”.

1.  Thermostat is set too low.

2.  Broken electrical connection 

between main PCB and motor. 

1.  Rotate thermostat to a higher 

setting

2.  Inspect all electrical connections 

(see wiring diagrams on page 11).

/DPSLVÀLFNHULQJDQG/('GLVSOD\

VKRZV³(´

1.  Thermostat switch has failed.

1.  Replace thermostat switch (see 

Wiring diagrams on page 11).

Poor combustion and / or excess 

soot production. 

1.

'LUW\LQSXWRXWSXWRUOLQW¿OWHU

2.

'LUW\IXHO¿OWHU

Poor quality of fuel.

4.  PSI is too high or too low. 

1.

&OHDQUHSODFHDLURUOLQW¿OWHU

2.

&OHDQUHSODFHIXHO¿OWHU

Flush fuel tank and refuel heater.

4.  Use proper pressure. 

Heater does not turn on and the 

lamp is not lit.

1.  Temperature limit sensor has 

overheated.

2.  No electrical power.

Fuse is blown.

4.  Improper electrical connection 

between temperature limit sensor 

and circuit board. 

1.  Push power switch to “OFF and 

allow heater to cool for 10 minutes. 

Restart heater. 

2.  Check power cords for proper 

connection and test the power 

supply.

Check / replace the fuse.

4.  Inspect all electrical connections 

(see wiring diagrams on page 11).

Содержание HK070F-A

Страница 1: ...rovided with this heater Failure to comply can result in fire or explosion that can cause property loss bodily injury or loss of life Only persons who can follow and understand these instructions shou...

Страница 2: ...dust particles volatile or airborne combustibles or any unknown chemicals This is an unvented portable heater It uses air Oxygen from the area in which it is used Adequate combustion and ventilation...

Страница 3: ...lung problems anemia or those under the influence of alcohol or at high altitudes 8VH WKLV KHDWHU LQ RQO ZHOO YHQWLODWHG DUHDV 3URYLGH DW OHDVW D WKUHH VTXDUH IRRW VT FP RSHQLQJ RI RXWVLGH DLU IRU HYH...

Страница 4: ...9 49 Pump Pressure psi BAR 4 0 0 26 7 5 0 45 9 0 0 55 Volts AC Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz Amps 1 5 2 7 2 8 Phase Single Single Single Single 6SHFL FDWLRQV VXEMHFW WR FKDQJH ZLW...

Страница 5: ...WUXFWLRQV Models HK070F A KDW V Q 7KH R Cord Wraps 2 Carry Handle 1 Black Screws 4 Carry Handle Assembly 1 Align holes in the upper housing with the 2 KROHV LQ WKH KDQGOH DV VKRZQ LQ LJXUH 2 Insert sc...

Страница 6: ...UEL SOURCE 5 Remove the heater and all packaging materials from the shipping carton Tools Needed Phillips Head Screw Driver 8 mm open end wrench 19 mm open end wrench VVHPEO QVWUXFWLRQV Models HK125FW...

Страница 7: ...WKURXJK WKH first hole from the front in the tank lip and tighten firmly Make certain all 4 screws are secure 7 Attach rear handle with 2 long screws 50 mm and 2 nuts through the third hole from the...

Страница 8: ...nlight or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER 127 HURVHQH VKRXO...

Страница 9: ...itch to On position The power indicator light and room temperature display will illuminate and heater will ignite See Figure 10 127 I LI WKH KHDWHU VWLOO GRHV QRW LJQLWH UHIHU WR 7URXEOHVKRRWLQJ XLGH...

Страница 10: ...head hole See Figure 12 03257 17 1HYHU VWRUH OHIWRYHU NHURVHQH EHWZHHQ VHDVRQV XVLQJ ROG IXHO FDQ GDPDJH KHDWHU 6HUYLFH DO NOT TAMPER WITH THE UNIT HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUS...

Страница 11: ...TER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean 1 K Kerosene Contaminated fuel could make cleaning the fuel filter necessary immediately...

Страница 12: ...should be cleaned or replaced at least once per heating season Contaminated fuel could make this necessary immediately To clean dirt from nozzle blow compressed air through nozzle front It may be nec...

Страница 13: ...connected to spark plug 9 Defective ignitor 1 Fill tank with fresh kerosene 2 Adjust pump pressure Clean replace spark plug 4 OHDQ UHSODFH IXHO OWHU 5 Clean replace nozzle 6 Rinse fuel tank with clea...

Страница 14: ...re Supply Pty Ltd Kerosene Forced Air Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 13 17 14 16 11 15 12 40 43 34 4 1...

Страница 15: ...70 028 0580 21 Motor 70 021 0501 70 021 0511 70 021 0521 70 021 0521 22 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 5RWRU LW 24 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020...

Страница 16: ...______________________________ ____________________________________________________________ ____________________________________________________________ _______________________________________________...