NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

© 2017, Lavorwash 

Kerosene Forced Air Heater User’s Manual 

Wiring Diagram

CONTROL PCB

POWER LAMP

(LED)

CN1

RED

RED

BLACK

BLUE

BLACK

BLACK

BLUE

RED

EARTH

GREEN

SPARK PLUG

IGNITOR

PUMP

MOTOR

CAPACITOR

3.5UF/450VAC

FAN 1

FAN 2

ACIN 1

WHITE

WHITE

EARTH

BLACK

WHITE

BLACK

GREEN

POWER

PLUG

AC 230V

50Hz

LIMIT 

CONTROL

POWER

SWITCH

PHOTOCELL

BLACK

BLACK

CDS

CN2

YELLOW

FUSE

5A/250AVC

ACIN 2

Maintenance

PUMP PRESSURE:

While heater is operating, turn adjusting screw 

clockwise to increase, counter-clockwise to 

decrease pressure. Correct pump pressure is as 

follows: 

Model Number

Pump Pressure

FF 45

3.0 PSI / 0.21 BAR

FF 70

3.7 PSI / 0.26 BAR

FF 125

4.5 PSI / 0.31 BAR

FF 175

6.5 PSI / 0.45 BAR

FF 215

8.0 PSI / 0.55 BAR

Tolerance ± 10%

NOZZLES:

Nozzles should be cleaned or replaced at least 

once per heating season. Contaminated fuel could 

make this necessary immediately. To clean dirt 

from nozzle, blow compressed air through nozzle 

front. It may be necessary to soak the nozzle in  

paraffin to loosen any dirt particles.

Figure 18

Adjusting Screw

Pressure Valve

Figure 19

Nozzle

Nozzle Face

Burner Head

11

Figure 20: FF 45

Figure 21: FF 70 / FF 125 / FF 175 / 

      FF 215

CONTROL PCB

CN1

ORANGE

PINK

BLACK

BLACK

BLACK

WHITE

EARTH

GREEN

SPARK PLUG

IGNITOR

PUMP

MOTOR

CAPACITOR

3.5UF/450VAC

(70T-KFA-EU)

7uF/450VAC

(125T-KFA-EU)  

(175T-KFA-EU)

(215T-KFA-EU)

MOTOR 1

MOTOR 2

ACIN 2

*

*

*

 

BLEU: FF 70

RED:   FF 125 / FF 125 / FF 215

ACIN 1

FUSE

5A/250AVC

GREEN

EARTH

BLACK

WHITE

AC 230V

50Hz

POWER

PLUG

BLACK

POWER

SWITCH

LIMIT 

CONTROL

PHOTOCELL

BLACK

BLACK

YELLOW

WHITE

WHITE

BLACK

BLACK

ROOM

SENSOR

R-TH

CN2

CN2

CDS

POWER LAMP

(LED)

THERMOSTAT

(TEMP. CONTROL

NOTE:

Models 125  / 175 / FF 215 have a 

digital display. 

Содержание FF 45

Страница 1: ...these instructions should operate or service this heater DANGER NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION INDOOR USE PERMITTED ONLY FOR THE TEMPORARY H...

Страница 2: ...G INSTRUCTIONS Failure to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot product...

Страница 3: ...foot 2 800 sq cm opening of outside air for every 100 000 Btu Hr heater rating Refer to Ventilation on page 7 for further instructions ALWAYS use only the electrical power voltage and frequency speci...

Страница 4: ...0VAC 50Hz 230VAC 50Hz 230VAC 50Hz Phase Single Single Single Single Single Specifications subject to change without notice Hot Air Outlet Upper Shell Lower Shell Fuel Tank Fan Guard Pressure Gauge Fue...

Страница 5: ...y 1 Align holes in the upper housing with the 2 holes in the handle as shown in Figure 3 2 Insert screws and tighten firmly Cord Wrap Assembly 1 Insert tabs into square slots in shell support and line...

Страница 6: ...ded Phillips Head Screw Driver 8 mm open end wrench 19 mm open end wrench Assembly Instructions Models FF 125 FF 175 FF 215 What s In The Box Tires 2 Axle Nuts 2 Spacers 2 Spare Drain Plug 1 Front Han...

Страница 7: ...rear handle with 2 long screws 50 mm and 2 nuts through the third hole from the rear of the heater on either side See Figure 6 8 Tilt the heater up gently so it is resting on the front handle NOTE DO...

Страница 8: ...er store paraffin in a red container Red is associated with gasoline Ventilation Risk of indoor air pollution and Carbon Monoxide Poisoning Use heater only in well ventilated areas Refer to Safety Inf...

Страница 9: ...perature setting The thermostat set range is from 4 5 C to 43 4 C 3 Move power switch to On position The power indicator light and room temperature display will illuminate and heater will ignite See F...

Страница 10: ...rvice DO NOT TAMPER WITH THE UNIT HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe...

Страница 11: ...ated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models FF 45 FF 70 turn filter 90 clockwise To remove the filter from models 125 175 FF 215 turn filt...

Страница 12: ...8 0 PSI 0 55 BAR Tolerance 10 NOZZLES Nozzles should be cleaned or replaced at least once per heating season Contaminated fuel could make this necessary immediately To clean dirt from nozzle blow comp...

Страница 13: ...plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh paraffin 7 Inspect all electrical connections See wiring diagrams on page 11 8 Re attach ignitor wire to spa...

Страница 14: ...URCE 2017 Lavorwash Kerosene Forced Air Heater User s Manual 13 17 14 16 11 15 12 40 42 46 34 4 19 17 3 5 35 8 7 1 2 9 28 29 27 32 21 22 23 31 26 30 24 18 55 47 49 50 39 38 6 45 44 43 36 10 41 20 33 3...

Страница 15: ...102 70 054 0102 70 054 0102 27 Output Filter 70 023 0100 70 023 0100 70 023 0100 70 023 0100 70 023 0100 28 Intake Filter 70 054 0101 70 054 0101 70 054 0101 70 054 0101 70 054 0101 29 End Filter Cove...

Страница 16: ..._______________________________________________ ____________________________________________________________ ____________________________________________________________ ______________________________...

Отзывы: