EN
24
into the machine for at least 10 minutes. The
delivery end of the line should discharge into a
canvas or mesh bag so that the scale removed
is not returned to the circuit. Then restore the
normal connection and rinse with plenty of
cold water. This operation should be carried
out by our after-sales service, since the descal-
ing product may cause wear of components.
Comply with the regulations in force when dis-
posing of the descaling agent.
> MAINTENANCE
IMPORTANT: Before doing any work on
the cleaner, discharge the pressure and
disconnect the electricity and water
supplies.
CHECKING THE PUMP OIL LEVEL
Check the oil level periodically. The oil must
be changed for the fi rst time after 50 working
hours, with subsequent changes every 500
hours. ISO 150 oil is recommended - Oil capac-
ity 0,45 Kg
CHECKING THE WATER INTAKE FILTER
Inspect and clean the water intake fi lter (ref. 11)
on the intake union periodically. This is impor-
tant to prevent fouling which may impair op-
eration of the pump.
REPLACING THE SPRAY ROD NOZZLE
Replace the nozzle when the pressure drops
below the normal values.
ELECTRIC MOTOR
If the motor malfunctions, it cuts out. Wait 5-10
minutes before restarting. If the problem per-
sists, refer to the “TROUBLESHOOTING” section.
If you are still unable to eliminate the problem,
stop using the machine and contact an Author-
ized Service Centre.
ELECTRICAL CORD
WARNING:
Take care not damage the elec-
tric cable. Have a damaged power cord re-
placed immediately by an authorized serv-
ice point or an electrical specialist.
CLEANING THE FUEL FILTER
Check the fuel fi lter (ref. 12) periodically and
replace if it has deteriorated or is excessively
dirty.
> ELECTRIC DIAGRAM
See illustrations, page 6.
> WATER DIAGRAM
See illustrations, page 6.
> TROUBLESHOOTING
Before doing any work on the machine, discon-
nect the electricity and water supplies and dis-
charge the pressure. Proceed systematically to
identify faults following the chart below; if you
are still unable to eliminate the problem, call in
the
Authorized After-Sales Service
.
Fault
When the main switch is
turned on the machine
does not start
Cause
• Plug not properly connect-
ed.
• Connection panel fuses
are burnt out.
Repair
• Carefully check the plug
and the electric cable.
• Check them and replace
them.
Fault
The motor hums but does
not start
Cause
• A phase is missing (in
three phase models).
• Lows voltage.
• High pressure pump is
blocked.