Superabrasive
Owner’s Manual Original Language – Lavina
®
V32-X-400-E
06/2019
17
6.1 AUTOMATIC FILTER CLEANING SYSTEM INSPECTION
Dust collector
LAVINA® V32-X-400-E has automatic filter cleaning system. There are two driving actuators, one for the
inlet valve and second for the valve of the suction head.
6.1.1 REPLACING THE ACTUATOR OF THE VALVE OF THE SUCTION HEAD
Unscrew the four screws (pos.1;fig.6.1).
Take out the cover (pos.2;fig.6.1), pull out the plate (pos.3;fig.6.1) .
Unscrew the nuts (pos.4,5;fig.6.1), the two screws (see pos.6,7;fig.6.1) and the two spacers (pos.8;fig.6.1).
Disconnect the two wires of the power cord (fig.6.2).
6.1.2 REPLACING THE ACTUATOR OF THE INLET VALVE
dismount the security cover with two
bolts /pos.1,2,3;fig.6.3/
remove the hairpin cotter pin
/pos.5;fig.6.3 / of the handle serving
as a front axle of the actuator
/pos.4;fig.6.3 / and remouve the axle.
Unscrew the bolt and the nut
pos.7,8;fig.6.3). Dismount the
actuator.
Disconnect the two wires of the power
cord
6.2 CLOSING FLAP REPLACEMENT
The closing flap on the bottom of the vaccum
container is separating the collected dust. It is
mounted on a spring-loaded lever. The spring-
loaded lever and the vacuum in the dust collector
keep the flap closed during operation.
To dismount the closing flap uscrew the two bolts
(pos.2 Fig.6.4)
7. TROUBLESHOOTING
Figure 6.4
Figure 6.2
Figure 6.1
Figure 6.3