Maintenance manual for technical assistance
Manual code 10081945 / Rel. 0.00 / February 2014
8
Lever with a screwdriver in the indi-
cated point and remove the front
cover (11).
Unscrew the two indicated screws
and remove the control panel (12).
Unscrew the indicated screw and re-
move the electronic board (13).
7.2. Disassembling the hydraulic supply unit
Disconnect the electrical connection
(1), pipes (2) and (3), tip and remove
the flowmeter (4).
Disconnect the pipes (5), (6) and (7)
removing the fixing clips.
Disconnect the pipe (8) in the lower
part of the pump. Disconnect the
electrical connections.
Unscrew the two screws shown in
the figure and remove the pump unit
(9).
11
C
12
13
A
A
4
2
3
1
5
6
7
8
9
A