DOS and Windows 3.x Installation
OS/2 Installation
1. With the power turned off, insert the DSerial-PCI
card into
any free PCI slot in your PC. Turn your PC on.
2. Place the DSerial-PCI
installation diskette into your floppy
drive. In the Win3.11\16550 subdirectory of this diskette you will
find a file called “Lavaconf.exe”. Copy this file to your hard drive and
run it.
3. When run, Lavaconf.exe will display two I/O addresses and one IRQ.
These correspond to the addresses and IRQ chosen by your PC when
configuring the DSerial-PCI
. Make a note of them.
4. If you are using Windows 3.x, start Windows and go to Control Panel
| Ports. Choose Com 3 for Port 1 and Com 4 for Port 2 on the DSerial-
PCI
. Click the Advanced button and enter the I/O address
and IRQ for each port as reported by Lavaconf.exe. Reboot your PC
for these changes to take effect.
Note: DOS & Windows 3.X support a maximum of four Com Ports in a PC.
Powered
Powered
Powered
Powered
1. With the power turned off, insert the DSerial-PCI
card into
any free PCI slot in your PC. Turn your PC on.
2. Place the DSerial-PCI
installation diskette into your floppy
drive. In the Serial\OS2 subdirectory of this diskette you will find a
file called “Setup.exe”. Running this file will install the DSerial-PCI
.
Note: Detailed installation instructions in English and French
are available on the installation diskette.
Powered
Powered
Powered
called “LavaPort”.This applet should now be used to configure ALL
Com Ports in your PC – not just Lava serial ports. Please note that
Com 1 may not appear in this applet if you have your mouse
attached to Com 1.