HEATER LOCATION
%
The heater is primarily for outdoor use only (see diagrammatical representations of outdoor areas). Do
not use it for indoors or in an enclosed area. Always ensure that adequate fresh air ventilation is
provided.
%
Do not use the heater for the heating of domestic premises.
%
Do not use the heater in the basements or below ground level.
%
This appliance shall only be used in an above ground open-air situation with natural ventilation, without
stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and
natural convection.
%
Any enclosure in which the appliance is used shall comply with one of the following:
-
An enclosure with walls on all sides, but at least one permanent opening at ground level and no
overhead cover.
-
Within a partial enclosure that includes an over head cover and no more than two walls.
-
Within a partial enclosure that includes an overhead cover and more than two walls, the following
shall apply:
--- At least 25% of the total wall area is completely open, and
--- At least 30% of the remaining wall area is open and unrestricted.
--- In the case of balconies, at least 20% of the total wall area shall be and remain open and
unrestricted.
%
This appliance shall be used only in an outdoor area and shall not be used in a building, garage or any
other enclosed area.
%
Always maintain clearance from combustible materials; from the top 60 cm, and sides 120cm
%
Heater must be placed on level firm ground.
%
Never operate heater in an explosive atmosphere like in areas where gasoline or other flammable
liquids or vapors are stored.