background image

Original Instructions 

8204216 

 

 

  (1) Gasoline Water Pump 

50      C       

         

                                                               

                                        Economic 

                                        Pump suction port dia(mm) 

(2) Gasoline High Pressure Pump 

40        C       

           

                                                                   

                                              Economic 

                                            Pump suction port dia(mm) 

 

H

ig

h

 

TYPE 

F40C(L) 

F40C(L)-2 

F50C(L) 

Suction port dia(mm) 

40 

40 

50 

Discharge port dia(mm) 

25x2;40x1 

50x1 

Capacity(m³/hr) 

17(at 35 m Head) 

12(at50 m Head) 

23(at 30m Head) 

Max.head(m) 

55 

95 

55 

Rated head (m) 

52 

90 

47 

Self-priming 

time(S/4m) 

30 

30 

30 

Max.suction head(m) 

6.0 

6.0 

6.0 

E

n

g

in

Model 

200P 

Rated power(kw) 

3.7 

Displacement(cc) 

196 

0.296 

Fuel 

tank 

capacity(1) 

3.6 

U

n

it

 

Gross weight(kg) 

23 

24.2 

26.5 

Outline 

dimension 

(LxWxH)(mm) 

560x460x565(L:560x475x680) 

Содержание MQ6638-FUZHOU

Страница 1: ...Original Instructions 8204216 GASOLINE WATER PUMP FIGURE SKU 8204216 Model MQ6638 FUZHOU GASOLINE HIGH PRESSURE PUMP FIGURE Fuzhou Launtop M E Co Ltd ...

Страница 2: ...Original Instructions 8204216 No 56 Jinshan Road Jinshan Industrial Park Fuzhou China ...

Страница 3: ...eal tool of irrigation and drainage Our company s Water High Pressure Pump series widely serve agriculture field industrial and fire fighting construction fishery garden etc The operation manual tells you how to operate and maintain your new Water High pressure Pump Please read it before use to ensure the proper handling and operation Follow the introduction carefully to keep your machine in the b...

Страница 4: ...Original Instructions 8204216 ...

Страница 5: ...RUCTURE AND USE 1 Main Structure 6 2 Main points of use 6 3 Procedure of use 6 4 Caution 7 5 Use and maintenance 7 6 Installation of connective soft pipe 9 CHAPTER 3 ANALYSIS OF MALFUNCTION AND REMEDY 10 CHAPTER 4 SPARE PARTS LIST 1 Part list of 1 5 inch F40 2 two impeller high pressure pump 12 2 Part list of 1 5 inch F40 high Pressure Pump 14 3 Part list of 2 inch F50 high pressure pump 15 4 Part...

Страница 6: ...8 17 23 Self priming time s 4m 70 120 180 max suction head m 8 8 8 Engine Model 160P 160P 240P Rated power kw rpm 2 76 3000 2 76 3000 4 9 3000 Displacement CC 163 163 242 Fuel tank capaity L 3 6 3 6 6 0 Unit G W kg 24 25 41 7 Outline dimensions L W H mm 495X395X405 545X405X455 635X505X570 2 Gasoline High Pressure Pump specifications and parameter Model LTP50C LTP80C LTP100C LTF40C LTF40C 2 LTF50C ...

Страница 7: ...n port dia mm 40 40 50 Discharge port dia mm 25x2 40x1 50x1 Capacity m hr 17 at 35 m Head 12 at50 m Head 23 at 30m Head Max head m 55 95 55 Rated head m 52 90 47 Self priming time S 4m 30 30 30 Max suction head m 6 0 6 0 6 0 Engine Model 200P Rated power kw 3 7 4 Displacement cc 196 0 296 Fuel tank capacity 1 3 6 Unit Gross weight kg 23 24 2 26 5 Outline dimension LxWxH mm 560x460x565 L 560x475x68...

Страница 8: ...antee store enough liquid in the pump body for next start The self priming pump s flow guidance and impeller are made from high strength cast iron high pressure pump s flow guidance and impeller are made from high quality die casting of aluminum alloy To meet different use high pressure pump can equip with different accessories 2 Main point of use 1 The coupling of suction pipe to the pump must be...

Страница 9: ...e of decrease can be estimated by minus local atmosohere value from 10m metre water column 2 Short and straight pipe is preferred as it can reduce unnecessary loss of pipeline The pipeline must be supported to avoid from vibrating and damaging the pump by oppressive Before operation you must check connection part between pump and pipeline whether there is loose phenomenon and pay special attention...

Страница 10: ...arance through adding or reduce the gasket in long shaft screw 8 When change machinery seal silent ring set NO 7 8 install in the pump cover movable ring set NO 1 6 install in the diesel output shaft Do not knock heavily when installing to prevent breaking the grind piece See Fig3 Fig 3 seal ring 1 graphite moving ring 2 seal ring 3 spring shim 4 compressde spring 5 moving ring seal 6 bottom seat ...

Страница 11: ...d air leak Change the machinery seal set The flow of water is not enough The filter net pipeline or impeller is Choked Clean up the obstruction Speed is low Increase speed Impeller of seal is wore seriously Adjust the gap or change impeller and machinery seal Inlet pipe leakage Check inlet pipe and connector of pipe change the pipe or screw down the bolt Impeller damage and leakage seriously Chang...

Страница 12: ...tations Check suction head and lower the position of pump Cause vibration or noise Suction head is too high and cause cavitations Check suction head and lower the position of pump Output of water is too large Decrease the output of water Inlet pipe is obstructed by foreign body so the resistance is too large Check inlet pipe and filter net to clean up Rotary part is loosed Listen carefully and ins...

Страница 13: ...Original Instructions 8204216 Impeller damage Stop the machine for checking and change the impeller with a new one ...

Страница 14: ...Original Instructions 8204216 ...

Страница 15: ...Original Instructions 8204216 ...

Страница 16: ...Original Instructions 8204216 ...

Страница 17: ...Original Instructions 8204216 ...

Страница 18: ...Original Instructions 8204216 ...

Страница 19: ...Original Instructions 8204216 ...

Страница 20: ...Original Instructions 8204216 ...

Страница 21: ...arming water 2 Type LTP50C LTP80C LTP100C LTF40C LTF40C 2 LTF50C 3 Serialnumber xxxxxxx xxxxxxx 4 Applicable EC Directives Machinery Directive 98 37 EC Additional used EC Directives EMC Directive 2004 108 EC 5 Used harmonized Standards EN809 1998 AC 02 A1 2009 6 Responsible for documentation Name address in EU Additional used EC Directives Directive 2002 88 EC against the emission of gaseous and p...

Страница 22: ...erson importing the products becomes responsible for ensuring that they comply with the directives which apply to them At very least it is recommended that the importer obtain a copy of the original Declaration of conformity from manufacture ...

Отзывы: