3. Performance index

4. Product Description

4.1. Instruction to structure

2

3

Visible light camera

Infrared imaging

sensor

Image capture key

Display Pixels
Infrared image resolution
visible image resolution
Field angle/shortest focus length
Thermal sensitivity
Temperature measurement range
Accuracy

-20

~450

℃)

Accuracy

300

~450

℃)

Emissivity
Frame rate of thermal images
Wavelength coverage
Focus mode

Color palette

View option
Storage medium
File format 

Automatic power-off time

USB

Power supply

Product size(length × width × height)
Product weight
Work temperature
Storage temperature
Relative humidity

320x240

Display screen
Screen size

TFT display screen 
3.2 inches

220x160
300,000 
27°x35°/0.5m
0.07

-20

 to 450

 (-4°F to 842°F)

±2% 
±10%

 

Adjustable from 0.01 to 1.0
9Hz
8-14um
Fixed
Rainbow, iron oxide red, cold color, 

black & white, white & black
The integration of thermal image with 

25% step length and visible image. 
Built-in 3G
JPG 

Built-in chargeable 18650 battery

Micro USB 2.0

Selectable: 5 minutes/20 minutes/ 

not power off automatically
90mm×105mm×223mm
389g
0

to 45

-40

 to 60

< 85

%

RH

Micro 

USB

Содержание TIT201

Страница 1: ...Instruction Manual Thermal Imaging Camera...

Страница 2: ...light camera The thermal images and visible images are stored in the device and can be read through USB or stored in a computer to generate a report or for print The supported operating system through...

Страница 3: ...ile format Automatic power off time USB Power supply Product size length width height Product weight Work temperature Storage temperature Relative humidity 320x240 Display screen Screen size TFT displ...

Страница 4: ...ition in the screen area It will move with the movement of the lowest temperature The cursor displays red The temperature value is displayed at the central position of the screen 5 1 Charging the prod...

Страница 5: ...ess MENU key to exit from the menu When viewing the images the screen will show the prompt of Delete photo by pressing key If yes is selected at the moment press MENU key to determine to delete the im...

Страница 6: ...ivided into materials with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct setting of the value of emissivity is very important for you to carry out t...

Страница 7: ...e Unit Time format Set time Spot Version 24h 10 8 3 The Emissivity Value of Common Materials Thermal radiation Black cloth Human skin Foam Charcoal dust Paint Matte paint Black rubber Plastic Timber P...

Страница 8: ...ged Press key to change the value After completing the change press SELECT ENTEER to enter After the time setting is completed press key to return Press MENU exit from the menu As shown in the figure...

Отзывы: