Launch TLT235
、
TLT240 Economical Two-post User’s Manual
12
5 Solutions to FAQ
Symptom Reason
Solution
Motor not operation
Check the circuit breaker or thermal
relay for tripping
Check the voltage to the motor
Check the electrical wiring
Limit switch is failed
♦
Motor wire is burnt
Close the switch of circuit breaker or
press the blue reset key of thermal relay
Supply correct voltage for motor
Correctly wiring as electrical system
diagram
Replace the limit switch
♦
Replace the motor
Motor is running, but
the lift can’t be raised.
Motor rotation reversed
Lowering valve body open.
Hydraulic pump sucks the air
Suction tube is separate from the
hydraulic pump
♦
Low oil level
Change the motor rotating direction
through changing wire connection.
Repair or replace the lowering valve
body
Fasten all the suction pipe fittings
Replace the suction tube
♦
Add the oil into the oil tank
Motor is running, the
lift can be raised
without load, but the
vehicle can’t be raised
Motor is running under low voltage
Impurities inside the lowering valve
body
Regulation pressure of safety valve is
incorrect
♦
Lift is overloaded
Supply correct voltage to the motor
Remove impurities from the lowering
valve body.
Adjust the safety valve
♦
Check the weight of the vehicle
The lift is lowering
slowly without
pressing the lowering
handle
♦
Impurities on the lowering valve body.
♦
External oil leakage
Clean the solenoid valve body
♦
Repair the external leakage
The lifting speed is
slow or oil flows out of
the oil fill cap
Air and oil are mixed
Air and oil suction are mixed
♦
Oil return pipe is loosened
Replace the hydraulic oil
Fasten all the suction pipe fittings
♦
Re-install the oil return pipe
The lift can’t rise
horizontally
Balance cable is not adjusted properly
♦
The lift is installed on the slop floor
Adjust the balance cable to the proper
tension
♦
Shimming the columns to level the
lift(no more than 5mm), If exceeding
5mm, pour new concrete floor and
make it leveled. Refer to installation
description.
Anchor Bolt is not
fastened
Hole is drilled too big
♦
Concrete floor thickness or fastening
force is insufficient
。
Pour the fast curing concrete into the
big hole and reinstall the anchor Bolt ,
or use new drill to drill the hole for
re-positioning the lift
♦
Cut open the old concrete and make
new concrete slab for the lift. Refer to
installation description.
Содержание L-235SB
Страница 11: ...Launch TLT235 TLT240 Economical Two post User s Manual 4 Fig 1b Fig 1c...
Страница 12: ...Launch TLT235 TLT240 Economical Two post User s Manual 5 Fig 2a Fig 2b...
Страница 30: ...Launch TLT235 TLT240 Economical Two post User s Manual 23 Fig 14a...
Страница 34: ...Launch TLT235 TLT240 Economical Two post User s Manual 27 Applicable to TLT235SC U TLT235SC TLT240SC...
Страница 36: ...Launch TLT235 TLT240 Economical Two post User s Manual 29 Applicable to TLT235SB TLT240SB...
Страница 37: ...Launch TLT235 TLT240 Economical Two post User s Manual 30 Applicable to TLT235SB TLT240SB...
Страница 38: ...Launch TLT235 TLT240 Economical Two post User s Manual 31 Applicable to TLT235SC TLT240SC...
Страница 46: ...Launch TLT235 TLT240 Economical Two post User s Manual 39 1 packing 1 packing Domestic...
Страница 47: ...Launch TLT235 TLT240 Economical Two post User s Manual 40 2 packing 3 packing 4 packing Extension column...