- 5 -
TECHNICAL SPECIFICATIONS
POWER SUPPLY and CONSUMPTION
(VDC)
12/24 VDC ±10%; 5 W
NO. OF LOAD CELLS IN PARALLEL and SUPPLY
max 16 (350 ohm); 5 VDC / 240 mA
LINEARITY / ANALOG OUTPUT LINEARITY
< 0.01% F.S.; < 0.01% F.S.
THERMAL DRIFT / ANALOG OUTPUT THERMAL DRIFT < 0.0005% F.S./°C; < 0.003 % F.S./°C
A/D CONVERTER
8 channels, 24 bit (16000000 points), 4.8 kHz
DIVISIONS
(with measurement range ±10 mV = sens. 2 mV/V)
max 1000000 0.01
V/d
MEASUREMENT RANGE
±39 mV
MAX SENSITIVITY OF USABLE LOAD CELLS
±7 mV/V
MAX CONVERSIONS PER SECOND
600 conversions/second
DISPLAY RANGE
±999999
NO. OF DECIMALS / DISPLAY INCREMENTS
0÷4 / x 1 x 2 x 5 x 10 x 20 x 50 x 100
DIGITAL FILTER / READINGS PER SECOND
0.006÷7 s / 5÷600 Hz
RELAY LOGIC OUTPUTS
N. 5 - max 115 VAC; 150 mA
LOGIC INPUTS
N. 3 - optoisolated 5 - 24 VDC PNP
SERIAL PORTS
RS485
BAUD RATE
2400, 4800, 9600, 19200, 38400, 115200
HUMIDITY (non condensing)
85%
STORAGE TEMPERATURE
-30°C +80°C
WORKING TEMPERATURE
-20°C +60°C
ANALOG OUTPUT
16 bit - 65535 divisions
0÷20 mA; 4÷20 mA (max 300 ohm);
0÷10 V; 0÷5 V
RELAY LOGIC OUTPUTS
N. 5 - max 30 VAC, 60 VDC; 150 mA
WORKING TEMPERATURE
-20°C +50°C
Equipment to be powered by 12-24 VDC LPS or Class 2 power source.