- 4 -
“ CELL ” (LOAD CELLS ALARM) : It appears when one or two signal wires are
disconnected, or the signal of the load cells is higher than 20mV.
TEST : LOAD CELL SIGNAL (mV) - INPUTS/OUTPUTS
Switch the instrument on by keeping pressed the
key, the LOAD CELLS VALUE ( expressed
in mV) will appear .
Press
, the “
1 ” message appears, press ENTER to close / open the relay 1, by
ensuring the changeover from “
” to “ _ _ _ ” when the relative input changes from open
to closed.
Press
, the “
2 ” message appears, press ENTER to close / open the relay 2, by
ensuring the changeover from “
” to “ _ _ _ ” when the relative input changes from open
to closed.
Press
, the “
3 ” message appears, press ENTER to close / open the relay 3.
Press
, the “ _ _ _ 4 ” message appears, press ENTER to close / open the relay 4.
Press
to exit until the weight is displayed.