JOLLY4 

   

4 different operating modes selectable 

 
 
 
 
 
 
 

 

          2014/30/EU (EMC)  -  2014/35/EU (LVD)

 

 

 

DATA TO BE FILLED OUT BY 
THE INSTALLER

 

 (Page 1) 

ENGLISH                 ENGLISH                 ENGLISH               ENGLISH

ENGLISH                 ENGLISH                 ENGLISH               ENGLISH

Содержание JOLLY4

Страница 1: ...user s manual version 3 3 JOLLY4 4 different operating modes selectable 2014 30 EU EMC 2014 35 EU LVD DATA TO BE FILLED OUT BY THE INSTALLER Page 1 ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENG...

Страница 2: ...ication label and or serial number of the product misuse transformation alteration repair of products not carried out by Laumas personnel Laumas provides a 1 year warranty from the date of the deliver...

Страница 3: ...V INPUTS OUTPUTS 4 INSTRUMENT START UP 5 THEORETICAL INSTRUMENT CALIBRATION 5 TARE ZERO SETTING 5 INSTRUMENT CALIBRATION CHECK AND CORRECTING DISPLAYED WEIGHT 6 WEIGHT INDICATOR WITH FOUR ALARM THRESH...

Страница 4: ...of 4 products Then press ENTER to restore the instruments the selected operating mode appears followed by the version s number If you press ENTER while JOL 4 0 is displayed the JOL 4 message will appe...

Страница 5: ...0 ohm or max 8 load cells 700 ohm INTERNAL DIVISIONS 20000 DISPLAY RANGE 999 19999 MEASURING RANGE 4 mV 16 5 mV READING RESOLUTION x 1 x 2 x 5 CONVERSION RATE 10 readings sec LOAD CELLS SIGNAL READING...

Страница 6: ...having the same colour perform the same operation for the shields By means of a shielded 4 wire cable with a section not lower than 0 5 mmq connect the terminal board to the JOLLY instrument The cabl...

Страница 7: ...message appears press ENTER to close open the relay 1 by ensuring the changeover from to _ _ _ when the relative input changes from open to closed Press the 2 message appears press ENTER to close open...

Страница 8: ...ells of 100 kg full scale 100 x 3 300 0 kg 10 of 300 0 kg 30 0 kg Confirm with ENTER the following will appear nU U set the load cell sensitivity expressed in mV V normally 2 000 using the and keys Co...

Страница 9: ...the cell and the cell loading position If the difference is not significant but around 1 2 then proceed to CORRECTING DISPLAYED WEIGHT FROM KEYBOARD CORRECTING DISPLAYED WEIGHT FROM KEYBOARD When the...

Страница 10: ...he weight for SET 1 max 9999 by using the and keys then confirm with ENTER the following will appear SEt 2 program the weight for SET 2 by using the and keys then confirm with ENTER the following will...

Страница 11: ...PAUS time has elapsed the instrument closes the cycle end contact led 4 the gross weight will appears When the unloading phase starts when the minimum weight is reached and the safe time emptying time...

Страница 12: ...ce the weight oscillations program a value included between 0 1 and max 9 9 seconds Confirm with ENTER to exit By pressing MENU you can exit in any moment 3CAr PROGRAM Loading batching of 3 products C...

Страница 13: ...top of the extractor 0 manual fall or 1 automatic fall The instrument will calculate on itself the fall value by using the arrows keys then confirm with ENTER the following will appear VOL 1 program t...

Страница 14: ...ontact led 2 when the SET2 value less the vol2 value is reached the SET2 contact will be opened after PAUS time has elapsed the instrument executes the autotare and closes the SET3 contact led 3 when...

Страница 15: ...r VOL 2 value of fall 2 Confirm with ENTER the following will appear VOL 3 value of fall 3 Confirm with ENTER the following will appear VOL 4 value of fall 4 Confirm with ENTER the following will appe...

Страница 16: ...product manuals are available online You can download the manuals in PDF format from www laumas com by consulting the Products section or the Download Area Registration is required Think about the en...