12

 

Circuit Diagram  

 
A1 

Electronic control power board 

A2 

Electronic control timer 

A3 

Electronic control temperature regulator 

A4 

Electronic control shaking frequency 

A5 

Pulse generator 

A6 

Interface inlet RS 232 

A7 

Line filter 

B1 

Temperature sensor PT100 

C1 

Motor condenser 

E1 

Tubular heating element 

F1 

Fuse 4 A T 

F2 

Fuse 4 A T 

F3 

Temperature limiter 

M1 

Fan motor 

M2 

Drive motor 

S1 

Main switch 

S2 

Control switch lid 

S3  

Change-over key for display of total run-time or entry of higher set points  

S4 

Entry of lower set points  

S5  

Switch off alarm signal 

S6  

Change-over key alteration of total run-time 

S7  

Confirmation of new total run-times 

S8  

Change-over key display and entry of higher set points 

S9  

Entry of lower set points 

S10  

Switch off alarm signal 

S11  

Change-over key alteration of set points 

S12  

Confirmation of new set points 

S13  

Change-over key display and entry of higher set points 

S14  

Entry of lower set points 

S15  

Shaking movement on / off 

S16  

Change-over key set points 

S17  

Confirmation of new set points 

V1 

Triac 

 

 

Содержание Varioshake VS 60 OI

Страница 1: ...Operating Instructions Varioshake Shaking Incubator VS 60 OI ...

Страница 2: ...2 26 Varioshake Shaking Incubator 09 2020 ...

Страница 3: ...e set from 20 min 1 to max 250 min 1 and oper ates with a fixed amplitude of 30 mm The micro processor controlled timer continuously displays the current remaining incubation time and emits an acoustic signal at end of time Control panel with main switch as well as display and operating elements of the timer and the electronic regulators for interi or temperature and shaking frequency Before insta...

Страница 4: ...4 26 Varioshake Shaking Incubator 09 2020 ...

Страница 5: ...ion via PC 12 Shutdown 12 7 Error Codes and Temperature Cut out 12 Error Codes 12 Temperature Cut out 13 8 Functional description 13 9 Maintenance Support and Repair 13 Cleaning and Disinfection 13 Temperature Adjustment 14 Checking the Acrylic Glass Cover 14 Shutdown caused by overload or power failure 14 Exchanging the fuses 14 Maintenance Procedures 14 10 Disposal of Old Units 15 11 Technical D...

Страница 6: ...6 26 Varioshake Shaking Incubator 09 2020 ...

Страница 7: ...n must not create an explosive atmosphere in the vicinity of the unit LAUDA Varioshake Shaking Incubators operated in a laboratory are no Medical Devices They fall neither under national nor international Medical Device Directives and have to be used and applied accordingly 2 Warranty For all laboratory apparatus and their accessories from LAUDA GFL Gesellschaft für Labortechnik mbH there is a war...

Страница 8: ...ng to the local regulations The Shaking Incubator is an electric appliance protection class I therefore a connection to earth conductor PE must be provided The value of the required mains fuse is stated in the technical data chapter 11 of these instructions The electrical connection must be configured so as to secure that power can be cut all pole at any time It must be secured that even after ope...

Страница 9: ...he connections of the cooling coil are situated at the back of the unit Cooling water is to be supplied to the Shaking Incubator through pressure proof water hoses with an interior diameter of approx 13 mm The connected hoses are to be secured with hose clamps hoses and clamps are not part of the standard scope of supply Operation and display elements of the control panel 1 Main switch Operation p...

Страница 10: ...ash and pilot lamp 4 glows display in minutes The required incubation time can now by set by pressing keys 6 and 7 max 59 minutes Press key 21 to confirm the set minutes The entry mode then switches to entry of set hours Pilot lamp 3 glows Use keys 6 and 7 to set the required incubation time in hours max 999 hours Press key 21 to confirm the set hours The timer is now activated the set incubation ...

Страница 11: ...ture alarms are signalled acoustically as well as visually by error codes in the display For further information on this subject please see chapter 7 1 Error Codes of these instructions When opening the Incubator s cover both heating and shaking drive will be switched off After closing the cover the Incubator will restart with the set values of temperature and shaking frequency Caution the tempera...

Страница 12: ...erior assembly of the Incubator must be carefully checked The Incubator must be operated in direct sight Take special care in the vicinity of the automati cally operated unit Shutdown To turn off the unit for longer shutdown times first switch the main switch to position O and disconnect the unit from the mains Empty the interior if necessary dry and clean the interior to prevent bacterial contami...

Страница 13: ...ly shows the current remaining run time and emits an acoustic expiration signal The electronic regulation is microprocessor controlled The housing is made of lacquered moulded ABS resin elements and of electrolytically galvanised and powder coated sheet steel The shaking platform made of anodised aluminium is equipped with four plastic pins for secure attachment of accessory equipment The heating ...

Страница 14: ...ncubator does not restart automatically but has to be started as described in chapter 6 Exchanging the fuses The unit s two fuses are situated in a drawer below the unit s plug In order to check or to exchange these fuses press the fixing clips on both sides of the drawer and pull The fuses may only be exchanged against 4 Amp fuses of the same type Information on the fuse type can be found on the ...

Страница 15: ... of charge and will have it materially recycled Before the unit is returned a legally binding declaration must be provided from the sender confirm ing that the unit is free from harmful and or hazardous contaminations as well as from hazardous substances caused by the previous use of the unit LAUDA GFL laboratory apparatus are exclusively designed for industrial use and may not be disposed of thro...

Страница 16: ...ronically settable up to 9 9 K above the set value to protect the test substances electronically settable up to 9 9 K below the set value to protect the test substances electromechanical temperature limiter with capillary tube sensor cut off temperature 135 C 10 K Shaking motion type Shaking amplitude Shaking frequency Incubation time orbital can be switched on and off 30 mm 20 250 min 1 depending...

Страница 17: ...tch S2 Control switch lid S3 Change over key for display of total run time or entry of higher set points S4 Entry of lower set points S5 Switch off alarm signal S6 Change over key alteration of total run time S7 Confirmation of new total run times S8 Change over key display and entry of higher set points S9 Entry of lower set points S10 Switch off alarm signal S11 Change over key alteration of set...

Страница 18: ...18 26 Varioshake Shaking Incubator 09 2020 Varioshake Shaking Incubator VS 60 OI ...

Страница 19: ...e assembled cast on shock proof plug CEE 7 7 Make sure to connect to a protective conductor terminal Colour decoding Stromnetz ge gr yellow green PE Protective earth bl blue N sw black L1 Electrical fuses Type Power Power consumption at mains voltage On site mains fuses F4 F5 VS 60 OI 0 65 kW 3 0 A at 230 V 10 A max 16 A see nameplate ...

Страница 20: ...9 0014315 Stand 10 A000073 Motor 0015531 Belt pulley for motor 11 A000112 Driving belt 12 0026285 Flat spring complete set 13 0013111 Temperature sensor PT 100 14 A000092 Temperature limiter 15 0030010 Mains connection cable 16 0012044 Plug 0012045 Drawer 0012902 Fuse 4A T 17 0013757 Microprocessor temperature regulator 18 0013759 Microprocessor shaking frequency display 19 0013768 Microprocessor ...

Страница 21: ...09 2020 Varioshake Shaking Incubator 21 26 When ordering spare parts please always state type and serial number oft he unit in question ...

Страница 22: ... length 75 160 mm Clamps for Erlenmeyer flasks made of stainless steel Supplied com plete with fixing material to be screwed onto a shaking tray Part No A000025 for 25 ml Erlenmeyer flasks Part No A000026 for 50 ml Erlenmeyer flasks Part No A000027 for 100 ml Erlenmeyer flasks Part No A000028 for 200 ml Erlenmeyer flasks Part No A000029 for 250 300 ml Erlenmeyer flasks Part No A000030 for 500 ml E...

Страница 23: ...f different vessels onto the shaking platform or tray Max shaking speed up to 250 min 1 depending on shape and weight of the vessel as well as on the shaking amplitude Dimensions 200 mm x 200 mm the mat can be cut or trimmed with scissors Operation temperature range 15 to 50 C Part No A000041 Adhesive mat black ...

Страница 24: ...24 26 Varioshake Shaking Incubator 09 2020 ...

Страница 25: ...09 2020 Varioshake Shaking Incubator 25 26 ...

Страница 26: ...LAUDA GFL Gesellschaft für Labortechnik mbH Schulze Delitzsch Straße 4 5 30938 Burgwedel Germany Tel 49 0 5139 9958 0 Fax 49 0 5139 9958 21 E Mail info lauda gfl de Internet www GFL de ...

Отзывы: