Power Manager II 

Hercules Development Kit

The Power Manager II Hercules Development Kit User’s Guide is available for download along with 

the latest USB drivers and design software at www.latticesemi.com/herculesdevkit. 
In the following steps, the evaluation board will be powered and made ready to run the pre-loaded 

demonstrations. Verify the jumpers J5 (VMON7) and J6 (VMON8) select the “12V_OR” option and 

not the “cPCI_HS” option.
1. Connect the AC adapter from a wall outlet to the power socket. After a connection is made to the 

12V wall adapter plug, the green PWR_3.3V interface LED (D14) will light up indicating the on-

board 3.3V regulator (U1) is operational. The Power Manager II will next illuminate three supply 

status LEDs: 12V_HS1.2V_SEQ, and PWR_GOOD (D1, D2, and D7). The TDO (D12) and 

data (D8 through D11) LEDs may also light up.

Run the Demonstrations

This step describes the functionality of the pre-configured Power Manager II Hercules demos:  

voltage supply trimming, supply margining, voltage monitoring, fault monitoring and logging.

Operation of the pre-loaded demos is accomplished by setting the demo DIP switches and pressing 

the mode switch (SW3). The following tables summarize the demo and switch settings pertaining to 

each of the pre-loaded demos. 
 

Demo

SW3

Up=1

Pressed=0

Demo DIP Switch Setting

Comment

Mode

VMON

7 6 5 4 3 2 1 0

Default

n/a

0 0 0 0 0 0 0 0 LCD self-test

1

1=CLT, 0=OLT

0 0 0 0 0 0 0 1 Trim 1.2V to <1% error; SW3 = trim mode;

VMON1/LCD = Measured supply voltage

2

1=CLT, 0=OLT

0 0 0 1 0 0 0 1 Margin 1.2V down 7.5%; SW3 = trim mode;

VMON1/LCD = Measured supply voltage 

2a

1=CLT, 0 =OLT

0 0 1 0 0 0 0 1 Margin 1.2V up 7.5%; SW3 = trim mode;

VMON1/LCD = Measured supply voltage 

3

n/a 

0 0 0 0 1 0 1 1 12V_HS voltage

VMON11/LCD = Measured supply voltage

4

n/a

0 0 0 0 1 0 0 1 Fault monitoring of slide potentiometer voltage (Vpot);

VMON9/LCD = Measured Vpot voltage (0V to 3.3V)

4a

1=Display 

0=Clear All 

1 x x x x x x x LCD = Total count of faults logged;

Press SW3 to reset count to zero

Demo

SW3

Default=1

Pressed=0

Demo DIP Switch Setting

Comment

Mode

VID

7 6 5 4 3 2 1 0

5

1=Hold, 0=Update 0 1 1 1 v8 v4 v2 v1

Add VID (DIP 0-3) value to 1.2V supply voltage;

VID (v8, v4, v2, v1) is a binary value multiplied by 10mV;

For example: 0000b=0*10mV=0V, 0100b=4*10mV=40mV, 

1000b=8·10mV=80mV; 1100b=12*10mV=120mV;

VMON1/LCD=Measured supply voltage

5a

1=Hold, 0=Update 0 1 1 0 v8 v4 v2 v1

Subtract VID (DIP 0-3) value to 1.2V supply voltage;

VID (v8, v4, v2, v1) is a binary value multiplied by 10mV;

VMON1/LCD=Measured supply voltage

5b

1=Hold, 0=Update 0 1 0 x x x x x Turn off 1.2V supply; VMON1=LCD

Notes: 

1.  The mode switch (SW3) is equal to a logic one (1) when not pressed. Pressing the mode switch (SW3) enters a logic zero (0).

2.  The demo DIP switches (SW5) are equal to a logic ones (1) when up. Placing the switches down makes them zeros (0).

3.  CLT means closed loop trimming mode (supply setpoint is trimmed to an accurate value). OLT means open loop trim to prede-

termined value (supply setpoint is a preset voltage and not trimmed). In other words, Demos 1 and 2 use either CLT or OLT trim 

mode depending on the condition of the mode switch (SW3).

4.  Pressing the PLD reset switch (SW4) resets the LatticeMico8 controller in the MachXO (U4), not the POWR1220AT8 (U3).

5.  The position of Interface Select Switches (SW2) does not affect any of the testing in the QuickSTART guide. 

Содержание Power Manager II Hercules

Страница 1: ...nents Please handle the kit components carefully Powering the Evaluation Board Running the pre loaded demonstration does not require connecting the provided USB cable to a PC The USB cable is required to modify the pre loaded demo interface to advanced demos or load pre configured designs Do not plug the USB cable into the PC until after loading Lattice s USB drivers included with ispVM The defaul...

Страница 2: ...asured supply voltage 2a 1 CLT 0 OLT 0 0 1 0 0 0 0 1 Margin 1 2V up 7 5 SW3 trim mode VMON1 LCD Measured supply voltage 3 n a 0 0 0 0 1 0 1 1 12V_HS voltage VMON11 LCD Measured supply voltage 4 n a 0 0 0 0 1 0 0 1 Fault monitoring of slide potentiometer voltage Vpot VMON9 LCD Measured Vpot voltage 0V to 3 3V 4a 1 Display 0 Clear All 1 x x x x x x x LCD Total count of faults logged Press SW3 to res...

Страница 3: ...o a fixed stored digital value and will not be as accurate as closed loop trim Demo 3 12V Voltage This is a POWR1220AT8 enabled version of the input 12V The input 12V can come from the 12V wall plug input or an external source This voltage exceeds VMON s 6V maximum input limit An intermediate voltage is created by dividing by a 4 1 resistor divider network The intermediate voltage is read at VMON1...

Страница 4: ...right 2010 Lattice Semiconductor Corporation Lattice Semiconductor L stylized Lattice Semiconductor Corp and Lattice design ispPAC LatticeMico8 MachXO and PAC Designer are either registered trademarks or trademarks of Lattice Semiconductor Corporation in the United States and or other countries Other product names used in this publication are for identification purposes only and may be trademarks ...

Страница 5: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Lattice PAC POWR1220AT8 HA EVN PAC POWR1220AT8 HS EVN ...

Отзывы: