background image

18

When installing the heating cable under tile or stone flooring choose one of the following methods:

1. Single Layer Method: 

LATICRETE does not recommend this method as it is impractical to lay tiles and can cause damage to the STRATA_HEAT™ Wire. However, 

when laying the tiles under the one-step method, start by applying thinset over the STRATA_HEAT Wire with the flat side of the trowel. 

Then add thinset on top of that with the notched side to prepare for the tile.

2. Double Layer Method: 

Embed the heating cable in a skim coat of self-leveling compound or modified thinset, completely covering compound completely covering 

the heating element and the sensor wire. Using a rubber float spread the thin-set over the floor in the same direction as the STRATA_HEAT 

Wire. Ensure that the space between the STRATA_HEAT Wire is filled. Allow this layer to dry completely.
Apply a second layer of thinset or adhesive and lay the tiles as usual. The required minimum total for both layers is 3/8" (9.5 mm) of 

thinset or adhesive. 
When deciding between the single layer or the double layer method you should consider the following: 
We do NOT recommend the single layer method if you will install mosaics or a combination of tiles of different sizes.
If this is the first time installing underfloor heating the double layer method is highly recommended. 

Waiting Period:

 

Ceramic tiles and stone installations require 1 to 3 weeks for the thinset to cure. Do not switch on the  

STRATA_HEAT floor heating system until you have allowed the thinset material to fully cure. Failure to do so will result in damage to the 

system and cause the thinset to become brittle.

Carpet, Vinyl or Laminate Flooring

Embed the STRATA_HEAT Wire in a layer of self-leveling compound and let it dry. Ensure that the heating cable are covered with a 

minimum of 3/8" (9.5 mm) of self-leveling compound.
Note : The under floor heating cables are NOT approved for direct contact with combustible material. The STRATA_HEAT Wire MUST 

always be embedded in thinset / cement mortar / cement based adhesive glue / tile adhesive before installing floating wood or 

laminate floors.

FLOOR COVERINGS – TILES & STONE 

Содержание STRATA_HEAT 0802-0017-2

Страница 1: ...al before attempting to install your STRATA_HEAT Wire Incorrect installation could damage the STRATA_HEAT Wire and will invalidate the warranty Globally Proven Construction Solutions Globally Proven C...

Страница 2: ...l Insulation 8 Floor Coverings 8 Subfloor Preparation 9 Controlling Your System 10 Wiring Diagram 120V 11 Wiring Diagram 240V 12 Electrical Provisions 13 Testing the System 14 Planning Your Installati...

Страница 3: ...inal outer jacket of PVC is given to make it sturdier and provide corrosion protection The heating cable is terminated at one end with a 10 3 1 m cold lead The conductor cores and ground braid are fac...

Страница 4: ...2 365 111 3 73 110 147 61 91 122 0802 0398 2 398 121 3 80 120 160 66 99 133 0802 0083 4 83 25 3 17 25 33 14 21 28 0802 0100 4 100 30 5 20 30 40 17 25 33 0802 0133 4 133 40 5 27 40 53 22 33 44 0802 016...

Страница 5: ...nstalling the floor covering for future reference DO ensure that the STRATA_HEAT Wire is separated from other heat sources such as luminaires and chimneys DO ensure that the minimum bending radius is...

Страница 6: ...EAT Wire under permanent fixtures DON T commence installation on a mud job screed that has not been fully cured DON T use the STRATA_HEAT Wire system until you have allowed sufficient drying period fo...

Страница 7: ...9 1 STRATA_HEAT WIRE SPECIFICATIONS 3 5 89 mm Spacing 240 Volt Area ft m Model Length ft m Wattage W Amps A Resistance 25 2 32 0802 0083 4 83 25 3 335 1 4 177 2 30 2 79 0802 0100 4 100 30 5 400 1 6 14...

Страница 8: ...up to 5 hours to heat a room whereas a system with thermal insulation takes less than an hour If the LATICRETE STRATA_HEAT Wire is being installed onto a concrete base it is highly recommended that a...

Страница 9: ...be applied and allowed to cure If the cable is being fitted to a solid floor it is essential that the concrete slab has been allowed to cure If using the HYDRO BAN Boards use a suitable cement based...

Страница 10: ...Wire has a maximum resistive load of 15 Amps Please refer to the table on page 7 to calculate the amperage load for your particular system For smaller areas you may be able to utilize an existing cir...

Страница 11: ...11 WIRING DIAGRAM 120V...

Страница 12: ...12 WIRING DIAGRAM 240V...

Страница 13: ...electrical metallic tubing or by other approved means The installation of electrical systems presents risks of fire and electrical shock which can result in personal injury Caution should always be ta...

Страница 14: ...circuit Place one probe on the black wire Place the other probe on the yellow red wire for 240V Resistance can vary significantly depending on the ambient temperature and an allowance of 5 from the no...

Страница 15: ...rovisions to ensure proper spacing of the cable The fixing guides included in the kit are 12 305 mm long with 1 25 mm spacing guides The perimeter STRATA_HEAT Spacing Strips should be installed a mini...

Страница 16: ...as this may damage both the factory joint and or the heating element within Secure the joint to the subfloor using duct tape Do NOT completely cover the joint in tape as this may create air pockets r...

Страница 17: ...floor probe into the channels and secure with fixing tape NOTE Do NOT run the cold lead wires and the floor sensor in the same conduit Installing the STRATA_HEAT Thermostat Instructions for the fitti...

Страница 18: ...layers is 3 8 9 5 mm of thinset or adhesive When deciding between the single layer or the double layer method you should consider the following We do NOT recommend the single layer method if you will...

Страница 19: ...s Now Install the STRATA_HEAT Wire into the gap which was created by the sleepers Carefully return the cold tail lead to the junction box or the STRATA_HEAT Thermostat alongside the STRATA_HEAT Wire a...

Страница 20: ...r Energy consumption will vary depending on user preferences For lower energy consumption set the STRATA_HEAT Thermostat to optimum temperature setting Energy consumption can be minimized by turning t...

Страница 21: ...er or LATICRETE You will need to locate the model information for the heater either on the product labels you kept or based on an invoice While incorrect grounding is the main cause for breaker trippi...

Страница 22: ...22 NOTES...

Страница 23: ...end user STRATA_HEAT Wire model number Resistance ohms Insulation Resistance M ohms Before During After Before During After Installation Address Date of Installation Electricians Details Name Signatu...

Страница 24: ...24 FLOOR PLAN...

Страница 25: ...your project with confidence n Customizable warranties are available to suit your specific project requirements CERTIFICATIONS LATICRETE materials are certified by independent laboratories throughout...

Страница 26: ...26 NOTES...

Страница 27: ......

Страница 28: ...ICRETE Park North Bethany CT 06524 3423 USA l 1 800 243 4788 l 1 203 393 0010 l www laticrete com 2017 LATICRETE International Inc All trademarks shown are the intellectual properties of their respect...

Отзывы: