Initial Set-Up
Towing (Hydrostatic Pump Release)
Initial Set-Up
9/27/19
3-6
3
4.
If either drive tire rotates, adjust the hydro-
static pump link arm for that tire. See Figure
3-3.
a.
Loosen the jam nut from the hydro-
static pump link arm.
(The jam nut is
located between the rod end and the
link arm).
See Figure 3-3.
a.
Slowly turn the link arm, watching the
tire as it turns.
a.
If the tire begins turning faster, turn
the link arm in the opposite direction
until it slows, and eventually stops.
a.
Tighten the jam nut to lock the link
arm into this position.
5.
When finished, turn off the drive unit.
6.
Ensure that both link arm jam nuts are tight.
7.
Lift the drive unit, remove the jack stands,
and lower the unit to the ground.
3.9
Towing (Hydrostatic Pump Release)
When towing your Articulator, it is necessary to allow the hydraulic fluid to bypass the
hydrostatic pump.
1.
Locate the bypass valve on the top of each pump.
2.
Turn the valves no more than (2) two turns in a counterclockwise motion.
The drive tires should rotate freely.
3.
Tow the unit to the desired destination at a slow speed.
4.
When towing is completed, return the valves to the original position by turning them in a
clockwise motion until they are tight (84-120 in-lbs).
Jam Nut
LT0108
FIG. 3-3