STATUS PAGE 

The Status page contains information on the operation of the product. It is the default web page. 
The following parameters are displayed: 

 
Device Type: 

displays the type of Cyclone module that is currently being viewed. This field will let 

the operator know the frequency band of the module, the protocol that it is utilizing, and the MAC 
address of the module.  

 
Software Version: 

displays the version of the software that is currently loaded into the module. 

Please make note of this information when obtaining technical support. 

 
FPGA Version: 

displays the version of the FPGA (field programmable gate array) that is 

currently loaded into the module. Please make not of this information when obtaining technical 
support. 

 
Uptime: 

displays the length of time the module has been operating since power was applied. 

 
System Time: 

displays the current time. If the access point module is connected to a Cluster 

Management Module (CMM) then the time will be Greenwich Mean Time (GMT). Any subscriber 
module that registers to the access point module will inherit the system time. 

 
Ethernet Interface: 

displays the configuration of the Ethernet interface on the module. 

 
Registered SM Count: 

This field displays the number of subscriber modules currently registered 

to the access point module. 

 
GPS Sync Pulse Status: 

displays the current status of the type of synchronization the access 

point module is receiving. There are 3 values that could be displayed: 

 

Generating sync

: If the module is set to generate its own sync pulse then this message 

will be displayed. 

 

Receiving Sync

: If the module is set to receive a sync pulse from an outside source (not 

itself) and is actually receiving the pulse then this message will be displayed. 

 

ERROR: No Sync Pulse

: If the module is set to receive a sync pulse from an outside 

source (not itself) and it is currently not receiving the pulse this message will be 
displayed. 

  When this message is displayed the access point module will turn its transmitter off so as 

to not create any self-interference within the Cyclone System. 

Radio Slicing Value: 

displays information to be used be Cyclone technical support. 

 
Radio Transmit Gain Setting: 

displays information to be used by Cyclone technical support. 

 
Site Name: 

displays information relating to the name of the physical module. This parameter can 

be set by the operator on the 

Configuration 

web page. This information is set into the 

sysName

 

SNMP MIB-II object and can be polled via a SNMP management server. 

 
Site Contact: 

displays contact information for the physical module. This parameter can be set by 

the operator on the 

Configuration 

web page. This information is set into the 

sysContact 

SNMP 

MIBII object and can be polled via a SNMP management server. 

 
 

CONFIGURATION 

The Configuration web page contains information and configurable parameters pertaining to the 
operation of the product. The first line of information on the Configuration screen is a repeat of the 

Device Type 

from the Status web page. The following are the parameters and their descriptions. 

 
 
 

Содержание Cyclone 900

Страница 1: ...separation distance of at least 60 cm approx 24 inches from all persons When so installed the module s RF field is within Health Canada limits for the general population consult Safety Code 6 obtaina...

Страница 2: ...ARTY FOR ANY DIRECT INDIRECT GENERAL SPECIAL INCIDENTAL CONSEQUENTIAL EXEMPLARY OR OTHER DAMAGE ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF...

Страница 3: ...tion areas to transport lightning strikes away from equipment GENERAL CONSIDERATIONS Fresnel Loss The Fresnel Zone is a theoretical area around the line of sight of an antenna transmission that can af...

Страница 4: ...izing a secret key On the Cyclone system DES encryption of the over the air link is done on a per access point module or backhaul timing master module basis and does not affect the performance or thro...

Страница 5: ...he cluster management module 10 Replace the base cover on all of the backhaul modules THE INTERFACE SCREENS The Cyclone backhaul module contains a series of web pages that are used to interface to the...

Страница 6: ...es that could be displayed Generating sync If the module is set to generate its own sync pulse then this message will be displayed Receiving Sync If the module is set to receive a sync pulse from an o...

Страница 7: ...is forgotten the operator will need physical access to the module and will need to create a Cyclone default plug See steps at the end of this section for use of a default plug LAN1 Subnet Mask enter i...

Страница 8: ...that MUST be used is root If the password is forgotten the operator will need physical access to the module and will need to create a Cyclone default plug to override the unit See steps at end of this...

Страница 9: ...nformation into the sysLocation SNMP MIB II object and can be polled by a SNMP management server The buffer size for this field is 128 characters Save Changes by clicking on this button any changes th...

Страница 10: ...st button The test will now run for the set duration If the web page is not set to automatically refresh click the Refresh Display button to see the results For a Cyclone System link to be considered...

Страница 11: ...s parameter is not present then a software version prior to release version 3 1 is on that module FPGA Version displays the version of FPGA that is running on the subscriber module If this parameter i...

Страница 12: ...r protocol inunknownprotos count displays the total number of packets received via the interface which were discards because of an unknown or unsupported protocol outoctets count displays the total nu...

Страница 13: ...band can either be in the 900 2 4 GHz 5 2 GHz or 5 7 GHz band The protocol for a subscriber module must be multipoint The MAC address will be in the following format 0a 00 3e xx xx xx Software Versio...

Страница 14: ...SNMP MIBII object and can be polled via a SNMP management server CONFIGURATION PAGE The Configuration web page contains information and configurable parameters pertaining to the operation of the produ...

Страница 15: ...cess to the module and will need to create a Cyclone default plug to override the unit See steps to create and use a default plug in the section on the Timing Master Webpage Auto Update enter time per...

Страница 16: ...o the module with Index 5 to view information about the link Frequency displays the transmit frequency of the access point module ESN displays the electronic serial number MAC address of the access po...

Страница 17: ...ly mode Choose the frequency to monitor from the pick list this would be the same frequency that the backhaul timing master module is transmitting on Click the radio button to highlight Enable on RSSI...

Страница 18: ...t mask of 255 255 0 0 then the first 16 bits of the 32 bit IP address identify the network 10101001 11111110 00000001 00000001 IP address 11111111 11111111 00000000 00000000 Subnet Mask There are 216...

Страница 19: ...r Meets FCC ISM ERP Limit DC Power 3A 24 VDC 7 2 watts Interface 10 100 BaseT half full duplex Rate auto negotiated 802 3 compliant Protocols Used by Cyclone IPV4 UDP TCP ICMP Telnet HTTP FTP SNMP DES...

Отзывы: