6. ELECTRONIC CONTROL INSTRUCTIONS
6-1-3. ERROR CODE TABLE
CODE
Content
Indicates
Refrigeration state
CO
C-sensor
- OPEN
- Normal operation
- Time control
Comp ON : 6 MINUTES
Comp OFF: 11 MINUTES
CS
- SHORT
(D1) (F3) (C1)
D-sensor
- OPEN
- SHORT
6-1-4. SENSOR DESCRIPTION
Sensor
Model
Role
Wire
Color
D-sensor
Freezer
Detect Evap coil's temp. to start and terminate
defrosting.
WHT
C-sensor
Freezer
Detect inside air temp. to operate comp and to
indicate the inside temp. on the display PCB
BLK
Refrigerator
Detect Evap coil's temp. to operate comp
BLK
T-sensor
Refrigerator
Detect inside air temp. to indicate the inside temp on
the display PCB
WHT