background image

4

Door Chime Options

You  can  program  the  LCD5511  keypad
to sound a tone when any zone is opened
or  closed.  There  are  two  parts  to  the
LCD5511 door chime programming:
• Program if the LCD5511 will chime 

when zones are opened and/or 
closed.

• Program the type of sound the 

LCD5511 will make when an individual 
zone is opened or closed.

For the door chime feature to work, you
will also need to turn on the Door Chime
attribute for each zone that will trigger the
chime. This programming is done in the
control panel software. Refer to your con-
trol  panel’s  Installation  Manual  for  more
information.

Door Chime on Zone Openings/

Closings

You can program each LCD5511 keypad
to  sound  a  door  chime  when  zones  are
opened and/or when they are closed. By
default,  LCD5511  keypads  are  pro-
grammed to sound door chimes on both
zone openings and closings. 
To change the door chime opening/clos-
ing settings, at each LCD5511 keypad:
1. Enter [

][8][Installer’s Code]

2. Enter [000] to go to keypad program-

ming

3. Enter section [6].
4. To turn the options on or off, press [6]

or [7]:

[6]ON  =Door  Chime  Enabled  for  Zone

Openings

OFF =Door Chime Disabled for Zone

Openings

[7]ON  =Door  Chime  Enabled  for  Zone

Closings

OFF =Door Chime Disabled for Zone

Closings

5. When you are finished, press [#] to exit.

Door Chime Sounds

You  can  program  the  LCD5511  keypad
to make different door chime sounds for
individual  zones,  or  groups  of  zones.
Each LCD5511 keypad can make any of

four  door  chime  sounds  for  each  zone
that triggers the door chime:

4 q uick beeps (default sound)

‘Bing –  Bing’ tone

‘Ding –  Dong’ tone

‘Alarm’ tone

NOTE:  For  a  zone  to  be  able  to  trigger  the
door  chime  sound,  the  Door  Chime  zone  at-
tribute must also be enabled in the control pan-
el programming. Please see your control panel
Installation M anual.

To change the door chime sounds:
1. Enter [

][8][Installer’s code].

2. Enter  [

]  to  go  to  door  chime  sound

programming.

3. Enter  a  2-digit  number  for  the  zone

you want to program [01] - [64].

4. Turn one of the following options on by

pressing [1], [2], [3], or [4]:

[1] 4 q uick beeps (default sound)
[2] ‘Bing –  Bing’ tone
[3] ‘Ding –  Dong’ tone
[4] ‘Alarm’ tone

NOTE: M ake sure that only one of the above
options  is  turned  on.  If  more  than  one  is  on,
the  keypad  will  sound  the  first  option  that  is
enabled. If none of the options are selected, the
keypad will not make any sound when the zone
is opened or closed.

5. To program the door chime sound for

another zone, repeat steps 3 and 4.

6. When  you  are  finished  programming

the  door  chime  sounds,  press  [#]  to
exit.

Zone Input/

PGM  Output Option

The LCD5511 ‘Z/P’ terminal can be pro-
grammed to support one zone input (de-
fault) or one PGM output. To change this
option:
1. Enter [

][8] [Installer Code].

2. Enter [000] to go to keypad program-

ming.

3. Enter section [6].

4. Turn the option on or off by pressing

[8].

Отзывы: