background image

Page 

4

CP-2502/2503/2510/2511/2513/2520/2521/2523/2530/2533

 

LASKOMEX PPUH

, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

JP1

100

136

124

K1

K2

K3

K4

K5

K6

M

J

G

K

D

P4

J

-      +

K1
K2
K3
K4
K5
K6

M

J

G

K

D

J

Adjustment of gain the microphone track in the panel

If there is need, the sensitivity of the microphone track can be adjusted with potentiometer
P4 in the external panel or with potentiometer P2 (microphone) in the electronic cassette.
Only adjustment with potentiometer P2 in the electronic cassette is suggested. If results are
not satisfactory then adjustment with potentiometer P4 should be done (position of the
potentiometer hand wheel should be maximal).

Volume control in external panel

If there is need loudness of the speaker in the external panel can be adjusted with potentiometer
P1 in the electronic cassette adjusting strength of the signal coming from uniphones – see
installation and usage manual of system CD-2502.

Jumpers settings.

Set properly jumper JP2 on the electronic panel plate (see figure 3).

Figure 3: External panel - setting the kind of used display and supplying camera

(only in video version) - in CP-2503.

Jumpers settings for video version panel:

Set properly jumper JP1 on the electronic panel plate (see figure 3).
Set properly jumper JP1 on the symmetrizator plate (

NOTE:

 not applicable for CP-2530) -

see figure 4. Value of the chosen resistance should be adequate to wave impedance of the
used cable. Standard setting is 100  adequate for UTP cable (

NOTE:

 for telephonic cables

ie. YTKSY o 0,5 mm set also 100 ).

Figure 4: External panel - setting output impedance in a panel in video version

- not applicable for CP-2530 and CP-25x3 panels.

Set properly jumper JP3 on the electronic panel plate (see figure 3).

JP3  camera and additional illumination on

JP3 camera and additional illumination off

JP1

JP2

JP3

JP1  continuous supplying camera - regardless of the jumper JP3

JP1  supplying camera while its illumination, according with EUc
 parameter - provided switching jumpers JP3

JP2  3 segments display

JP2  4 segments display

Содержание CP-2502 Series

Страница 1: ...OF PANELS CP 2502xxx CD 2503xxx CP 2510xxx CP 2513xxx CP 2511xxx CP 2520xxx CP 2523xxx CP 2521xxx CP 2530xxx CP 2533xxx DIGITAL ENTRY PHONE SYSTEM CP 2530 CP 2533 CP 2520 CP 2523 CP 2510 CP 2513 CP 2...

Страница 2: ...ud may cause faulty operation in such case dirt should be immediately removed Do not clean the panel with gasoline solvents or strong detergents as it may cause damage of the device surface 2 OUTDOOR...

Страница 3: ...N panel b in CP 2530 CP 2533 panels 3 DIGITAL ENTRY PHONE SYSTEM CD 2502 ADJUSTMENT The elements of entry phone system are preliminarily adjusted and unless it is necessary the position of potentiomet...

Страница 4: ...s see installation and usage manual of system CD 2502 Jumpers settings Set properly jumper JP2 on the electronic panel plate see figure 3 Figure 3 External panel setting the kind of used display and s...

Страница 5: ...uld be considered and set properly jumper JP2 and JP3 figure 3 NOTE Correct work of RFID function in CP 25xxR panel ensure cooperation only with EC 2502R electronic cassette 5 TECHNICAL DATA El supply...

Страница 6: ...mps 50m 150m 250m EC H CVP 1 L L LM L 0 5mm 2x0 5mm 3x0 5mm NC1 NC2 C C 0 5mm YTKSY UTP LAN T11 XzTKMXpw YTKSY UTP LAN T11 XzTKMXpw Clamps Distance CP EC CVP 15m Kx Kx 0 5mm X GX X GS 0 5mm C C NC1 NC...

Страница 7: ...AC 0 8 A Wh i te Br o w n AC2 AC1 CP xxxx 12 V AC 1 A AC4 AC3 Brow n Br o w n L L K6 K5 K4 K2 K3 K1 X GS K6 K5 K4 K2 K3 K1 X GX GZ VZ KZ GZA VZA VS GS NC1 NC2 C C CS CVP 1 SUBORDINATE ENTRANCE Electro...

Страница 8: ...DA 2V DA 3V 10 100 634 210 80 130 130 42 48 48 48 48 10 otw O 5 5 56 65 48 185 210 130 80 38 31 10 100 424 210 80 130 130 42 48 48 48 48 10 otw O 5 5 56 65 38 31 185 42 100 214 10 130 48 48 5 otw O 5...

Страница 9: ...8 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl DAX1 1 DAX1 2H DAX1 2V Figure 12 Dimensions of over plaster casing in vertical position for CP 2510 and CP 2513 panels Fi...

Страница 10: ...88 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl DAX2 1 DAX2 2H DAX2 2V Figure 14 Dimensions of panels CP 2520 CP 2523 NP2522 and NP2521 Figure 15 Dimensions of over pl...

Страница 11: ...0 2533 LASKOMEX PPUH ul D browskiego 249 93 231 d tel 42 671 88 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl Figure 18 Dimensions of over plaster casing in vertical pos...

Страница 12: ...s product was marked with a symbol of crossed dustbin according to European Directive 2002 96 WE on used electric and electronic equipment Used equipment cannot be placed with other wastes from househ...

Отзывы: