Laskomex Bastion Orion II Скачать руководство пользователя страница 11

button 

 (view). Pressing the button again will switch the view to the next entrance,

and pressing the button yet again will switch off the camera view.
- sequential operation. To activate voice communication in the camera view mode,
press the button    (talk).
- To accept a redirected call, press the button    (talk).
- The MVC-7002 monitor features controls for volume, brightness and colour saturation
adjustment (see Fig. 1).

7. Video doorphone maintance

Components of the video doorphone should be cleaned with a wet cloth or with cleaning
agents designed for plastics.

ATTENTION!

Do not use solvents or abrasive cleaners, as they can result in permanent damage to
the surface of the casing! Avoid any contact of doorphone components with water or
cleaning agents, as this might result in damaging the device and electric shock!

8. Technical data

Monitor MVC-7002

Screen size

5,8’’

Dimension

220x110x28mm

Supply voltage

15V DC/0.8A

Operation temperature

0°C...40°C

BVC-7002 external panel

Dimension

250x120x50mm

Operation temperature

-20°C...55°C

Degree of protection 

IP55

Supply voltage 

15V DC/0.12A

Angle of view vertical/horizon 82°, 62°
Angle adjustment           +/- 15° horizon, +/-10° vertical

Power supply

1500120W1EU or             GP005E-150-100

Input voltage

              230V AC                          

  230V AC

Output voltage

              15V DC/1,2A max.                15V/1A

Dimension

81x43x67mm  

        

  81x43x67mm

Operation temperature

0°C...40°C

                 0°C...40°C

Degree of protection 

IP40

       

                 IP40

11

 LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

Содержание Bastion Orion II

Страница 1: ...Bastion Orion II Video door phone set...

Страница 2: ...mounted 5 Electric installation of video door phone 6 Block diagrams 7 Connection diagrams 7 5 Assembly and connecting elements of video door phone 9 Assembly and connection MVC 7002 monitor 9 Connec...

Страница 3: ...or fire The external panel should be installed in a place with low noise level Video door phone elements should be connected to an electrical installation when the feeder is disconnected from the pow...

Страница 4: ...ounted and equipped with a door strike relay activated on pressing the monitor button Rys 2 External panel BVC 7002 a behind b front c Description of clamps 4 Fig 1 MVC 7002 video monitor a b Descript...

Страница 5: ...ose to the lamp window etc as it may obstruct viewing image on the screen Do not mount the monitor in place where it could be exposed to humidity e g in bathrooms Do not mount the monitor near the sou...

Страница 6: ...ables The number of wires in the cables is shown on the single line diagram fig 4 NOTE It is necessary to pay special attention on quality of connection s wires and also on proper isolation of every c...

Страница 7: ...apartments houses remove Jumper 3 JP3 on all monitors KSAD 1500120W1EU or GP005E 150 100 KSAD 1500120W1EU or GP005E 150 100 KSAD 1500120W1EU lub GP005E 150 100 KSAD 1500120W1EU lub GP005E 150 100 KSA...

Страница 8: ...KSAD 1500120W1EU or GP005E 150 100 KSAD 1500120W1EU or GP005E 150 100 KSAD 1500120W1EU lor GP005E 150 100 J101 230V AC 15V DC 1 2A 15V DC 1 2A 12V AC 1A audio masa wideo Red Blue White Yellow 15V DC...

Страница 9: ...itional monitor and connect the two monitors See Figure 4 5 and 6 Set jumper JP2 in the last most remote monitor from external panel JP2 Matching impedance to the coaxial cable 9 Rys 7 Connectors in M...

Страница 10: ...dditional monitor has been installed the camera view will display on both monitors To switch on voice communication press the button talk see Fig 1 In two monitor installations if voice communication...

Страница 11: ...ce of the casing Avoid any contact of doorphone components with water or cleaning agents as this might result in damaging the device and electric shock 8 Technical data Monitor MVC 7002 Screen size 5...

Страница 12: ...www laskomex com pl website or telephone No 42 671 88 68 Product packing should be removed according to environment protection regulations Remember Selective collection and recycling of used electron...

Отзывы: