COD. 83119L.01EN
09//2016
26
6.1.3
- ADJUSTMENT OF THE POWER FUNCTIONING
The stove has 6 range powers functioning, being 1 the lowest and 6 the highest. The user chooses from 1 to 6 by
a short keystroke
“clic”
of the button
(P3).
Besides the option to choose among the 6 powers, the panel control offers to us an automatic functioning mode
“A” in which the stove decides the more suitable power functioning in every moment modulating dependent on
room temperature and the temperature selected by the user. In this way, we get a faster heating, more constant
temperature and less fuel consumption.
To choose the power, push the button
(P3) and the display that is below will start to flicker.
With every
"clic"
of the button the power will increase more and more and, eventually, the automatic option will
appear. If we push the button again, the power starts again from power 1.
When we quit pushing, the value that appears in the display stops flickering and becomes as the new power of
functioning.
When the stove is stopped the functioning power does not appear, but if we push the button
(P3)
(“clic”)
, it appears the power that is selected and it can be changed.
6.1.4
- PELLET MANUAL LOAD
This function allows us, before turning on the stove, start up the load auger to fill it of pellet.
To do that we will push the button
(P3)
for some seconds
and the load auger will be activated constantly.
While in the display that is below it appears
“LoAd”
, the display on top indicates the time that it has been working.
We will interrupt the load when the pellet falls off steadily in the burner, for which you just have to push any button.
Due to security reasons, the load will be interrupted automatically after 300 seconds.
After having carried out this operation, before proceed to turn on the stove it is necessary to
empty the burner and go back to place it correctly. If the pellet accumulates too much while
turning on the stove, it could produce an explosion.
This function will only be activated when the stove is stopped.
It is necessary to carry out this operation before the first time we turn on the stove as well as in
case the stove runs out of pellet.
6.1.5
- ADJUSTMENT OF THE ROOM THERMOSTAT
AND
The user has the option to choose the room temperature desired in a range from 10º C to 40º C.
During the functioning, the stove compares the parameter value with the temperature that the room thermostat of
the rear side detects. While the room thermostat is below the room temperature, the stove works in the selected
power (or in automatic mode), and when it reaches that temperature changes into modulation
“mod”.
If while we are in modulation, we exceed in more than 2º C the selected temperature, the stove will turn off to
change into
“stand-by”
. The stove will turn on again when the room temperature is lower than the selected by the
user.
To modify the parameter value of the room temperature is enough a short keystroke
“clic”
in the button
or
(P2 or P4). In the display that is below we will see the temperature that was selected flickering
“th”
, which can be
increased or decreased by pushing the buttons
or
.
After 5 seconds, the new value is saved and the display returns to the main screen.
Содержание AUDAX 6 KW
Страница 1: ...LASIAN Heat Technology S L PELLET STOVE 6 8 10 12 KW USER AND INSTALLATION MANUAL...
Страница 2: ...COD 83119L 01EN 09 2016 2...
Страница 4: ...COD 83119L 01EN 09 2016 4 STOVES 6 8 10 12 KW 6 kW 8 kW 10 kW 12 kW...
Страница 46: ...COD 83119L 01EN 09 2016 46 TAS INTERVENTIONS DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...
Страница 47: ...COD 83119L 01EN 09 2016 47...