Manual: Laserworld Purelight Series
page 9 / 69
English
8. General Operation
1. Power
Connect the power cord to the device and to the mains. Make sure that your device is pro-
vided with the correct voltage. Wrong voltage could lead to irreparable damages. Please
find the correct voltage data in the synoptical table at the end of this manual. Make sure
that the device is not directed to people or inflammable objects during installation. To
start the device, connect the interlock bridge, insert the key and switch it on, and switch
the device on.
The “Emission - Laser on“ LED at the front side of the device begins to
light up when the device is ready for use.
2. Key Switch
There is a key switch at the back of the laser system. Please plug the key to the switch and
turn it on. The laser device only runs when the key is inserted and switched on.
Prevent
misuse! Unplug the key when the laser is unattended to prevent misuse of the sys-
tem.
3. Fuse
There is a fuse at the back side of the device. If the fuse should blow, please exchange
it with a new one. If the problems recurs, please contact your dealer or the Laserworld
service department.
4. Safety Presets
This device has an integrated Scan Safety (SFS). Is the Scan Safety active (on), single be-
ams are prevented. If the Scan Safety is switched off, it is possible to create full power
single beams - be careful!
Operating the laser system with disabled SFS may not be allowed in some countries.
Always ensure that maximum permissible exposure (MPE) is not exceeded in areas
accessible to the public or members of staff.
5. X / Y Inversion
Use the X, Y, and/or X/Y buttons to invert the beams resp. patterns on the x-axis and/or
y-axis.
6. Microphone Sensitivity
Set the microphone sensitivity by the ‚Sens‘ knob. This setting is needed for music mode
/ sound sensitive operation.
7. Colors (not available for PL-6000G & PL-12.000G)
Use the ‚red‘, ‚green‘ and ‚blue‘ knobs to control the intensity per output color channel.
8. Modes / Functions
The different operation modes can be selected with using the DIP switches at the back of
the device.
Any change of the operation mode requires a restart of the device
(switch
the device off and on again or disconnect power and reconnect it again). Do not change
any DIP switch settings during operation. Random and dangerous laser output can occur.