The laser must only be used for shows. Any operation has to be attended and 
supervised by a skilled and well-trained operator.   
Never leave this device running unattended and keep it away from children and 
unauthorized persons. 
Keep away from heaters and other heat sources. In order to safeguard sufficient 
ventilation, leave 50 cm of free space around the device. 
Never direct the laser beam to people or animals. 
CAUTION LASER DIODE: If you open the device for cleaning, always disconnect from 
mains! 

-

HEALTH HAZARD! Never look directly into the light source, as 

sensitive persons may suffer an epileptic shock!

 

These lasers are considered a definite eye hazard, 
particularly at the higher power levels, which WILL cause 
eye damage. So these laser series models supplied with a 
key switch to prevent unauthorized use, warning labels 
and aperture labels affixed to the laser. 

Installation safety

 

Prior to installation and operation of the laser, the paths of the 
beams and effects should be considered, particularly with 
respect to how they will reach the audience. If direct audience scanning is desired, then the 
laser energy in the effects needs to be considered to decide if the effects are safe for direct 
viewing. Always ensure, that the maximum permissible exposure (MPE) is not exceeded in 
the area accesible to the public. So install the laser in such a way, that minimum distances 
and heights ensure the MPE is never exceeded in the public area. 

OPERATING THE LASER 

The operator has to make sure that laser radiation – also reflected laser radiation – higher 
than the maximum permissible level is avoided by technical or organisational measures. 
(Especially with respect to the MPE, see above.) 
Make sure to use the correct voltage 
If the device is used in a flying installation, the mounting brackets and an appropriate safety-
rope must be fixed. 
In some countries, the operator must notify the accidence insurance and the authority for 
industrial safety, before operating a laser. For more information, contact the relevant 
authorities. 
Please consider that unauthorized modifications on the device are strictly forbidden due to 
safety reasons! 
If this device will be operated in any way differently than described in this manual, the 
product may suffer damages and the guarantee becomes void. Furthermore, any other 
operation may lead to dangers like short-circuit, burns, electric shock, etc. 
Keep surrounding dry and clean. T

his unit should be keep dry, do not use in the rain or 

damp and dusty environment. Projector should be put in a water-proof housing when 
operated outside.  
Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog 
fluid condenses in the housing (if so rearrange hazer and/or laser position). 
Operating temperature is 10~35

°C

. In a new installation, check after some 15-30 minutes 

whether the outlet air gets too warm. Regularly check the inside for dust deposits, especially 
around the fans. Let laser cool off 10minutes after 2 hours of operation,to ensure maximum 
lifetime for the diode. 
Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 

Содержание MH-OEM

Страница 1: ...MH OEM OEM housing without laser sources USER MANUAL ...

Страница 2: ...TENANCE 8 7 TECHNICAL SPECIFICATIONS 8 8 ELECTRICAL DRAWING 9 9 PROBLEM AND ANSWER 10 10 APPENDIX ILDA PINOUTS 11 Checking Parts Please check if the following parts are included 1 x MH OEM Laser 1 x Power cable 1 x User manual SAFETY INSTRUCTIONS If the device has been exposed to great temperature changes do not switch it on immediately Condensation water may damage your device Leave the device sw...

Страница 3: ...ING THE LASER The operator has to make sure that laser radiation also reflected laser radiation higher than the maximum permissible level is avoided by technical or organisational measures Especially with respect to the MPE see above Make sure to use the correct voltage If the device is used in a flying installation the mounting brackets and an appropriate safety rope must be fixed In some countri...

Страница 4: ...y especially not with optical instruments Do not touch the device with wet hands When the laser diode becomes dim or broken please contact your dealer timely When returning laser to dealer manufacturer always use original packaging Maintenance should be performed every 15 day period See cleaning further down ...

Страница 5: ...USER MANUAL Laserworld Moving Head MH OEM Date 09 2010 Page 5 of 12 ...

Страница 6: ...USER MANUAL Laserworld Moving Head MH OEM Date 09 2010 Page 6 of 12 ...

Страница 7: ...ilt speed Pan tilt speed 253 255 Reset Reset 6 0 127 Switch to internal 128 255 Switch to SD card 7 0 255 Bank Bank 8 0 255 Pattern Frame 9 0 255 Size Size 10 0 255 Colourgroup Colourgroup 11 0 255 Intensity blue Intensity blue 12 0 255 Intensity green Intensity green 13 0 255 Intensity red Intensity red 14 0 255 Master intensity Master intensity 15 0 255 V roll V roll 16 0 255 H roll H roll 17 0 ...

Страница 8: ...en the device is not in use or before cleaning it 7 TECHNICAL SPECIFICATIONS LW50k scanner system deflection angle max 60 op tical scanspeed max 50 000pps ILDA 25pin ILDA Standard Sub D shaped 25pin connector Control mode ILDA DMX 512 sound automatic mode DMX 512 20 channels basic patterns 160 Movement Pan 530 Tilt 280 16bit resolution Display digital display at the back Accessories power cable mo...

Страница 9: ...USER MANUAL Laserworld Moving Head MH OEM Date 09 2010 Page 9 of 12 ...

Страница 10: ...USER MANUAL Laserworld Moving Head MH OEM Date 09 2010 Page 10 of 12 ...

Страница 11: ...USER MANUAL Laserworld Moving Head MH OEM Date 09 2010 Page 11 of 12 ...

Страница 12: ...WITZERLAND Authorized person Supervisory board Mr Martin Werner place of business 8574 Lengwil Oberhofen SWITZERLAND company number CH 440 3 020 548 6 Commercial Registry Kanton Thurgau www laserworld com info laserworld com representative according to EMVG Cleantech Europe GmbH Managing Director Thomas Schulze Fürkhofstr 5 81927 München DE ...

Отзывы: