Back Side of Mirror 3
Small burn mark
Figure 2
Position X axis to P2 (Bring it all the way forward)
Put a small pen mark to the side of this dot so you will know
which dot was fired first.
Repeat step in
on previous page to create second dot.
If the dots are on top of each other you are done with mirror 2.
Please go to page 6 for basics of beam alignment read the
directions on how to do all but you can skip adjusting Mirror 2’s
Prism Mount
If you have two separate burn marks continue with this page.
Orange
1
2
If your dots look something like this you need to adjust mirror 2.
Please note your Red Dot will NOT line up with your burn marks.
Do not attempt to line Red Dot up it will not be in the same
spot as the C02 beam.
Dot 1 is from P1 and 2 is P2.
P1 dot will never move. We need to adjust the dot at P2 to
hit the one from P1.
Remember to always wear safety glasses while doing any open beam tests.
(Place Pen mark just to left of burn mark for later identification as shown)