12.5- Rapid Calibration Service: 

 

Typical turnaround times for the Rapid Recalibration Service, are 10 business days. These turnaround times occur 
after the items have been received by LaserPoint Service Center, and do not include transit times.       
a) faster  re-calibration times  are free  of  charge  but must  be  booked in advance:  contact 

[email protected]

 and 

ask for the first available time slot that can be reserved for calibration;  
b)  The following information must be included in the calibration request, sent by fax or email:  the re-calibration 
wavelength(s),  if  recalibration  is  to  be  performed  for  Power  or  Power  +  Energy,  and  the  product(s)  model  and 
serial  numbers.  A  Purchase  Order  for  the  Calibration  Service  is  sufficient  and  no  RMA  (Return  Material 
Authorization) form is needed. 
c)  LaserPoint  will  communicate  the  first  available  time  slot  and  customers  are  requested  to  ensure  that  the 
products arrive in advance of the agreed upon date. 
d)  Items that do not conform to the fast re-calibration  policy will be placed in a queue, where the first items to 
arrive will be calibrated first. 
 

12.6- Re-calibration Procedures and Timing: 

 

 For re-calibrations, a Purchase Order for this service is acceptable, and a return materials authorization (RMA) 
form is not necessary.  
Ensure that the shipping documents include your PO number. 
1-  It  is  mandatory  that  the  PO  includes,  for  each  sent  item,  the  following  information:  the  re-calibration 
wavelength(s),  if  recalibration  has  to  be  performed  for  Power  or  Power  +  Energy,  and  the  product  model  and 
serial numbers. 
POs with incomplete information cannot be correctly processed, and the time required for re-calibration will be 
extended until all the information has been received. 
2- Shipment costs to and from LaserPoint are at the customer's expense. 

 
 12.7- Return Material Authorization ( RMA): 

 

Comply to our return and shipping policy conditions: 
a)  LaserPoint  product  cannot  be  returned  directly  to  LaserPoint  without  first  asking  for  a  Return  Material 
Authorization (RMA) number. 
b) If the customer submits items when an RMA number has not been issued, then the items will be returned to the 
customer at the customer’s expense. 
c) LaserPoint or its authorized third parties are the only entities authorized to repair or replace defective parts or 
products, in accordance with the internal procedures at LaserPoint. 
d) After the items are serviced, the items will be shipped back to the customer, provided that all issued invoices 
have been paid in full, prior to performing the servicing, unless different terms were agreed upon. 
 

Instructions for returning equipment: 

1- Ask LaserPoint (

[email protected]

for an RMA number prior to shipping any product to LaserPoint. 

2- Fill in the Customer RMA Form that is provided by LaserPoint Customer Service. 
3-  The  RMA  number  has  to  be  clearly  written  on  all  related  documentation  and  on  the  outside  of  the 
package.  
4- Ship items through a traceable carrier.  
5- LaserPoint is not liable for damage that occurs during shipping. 

 

12.8- Limited Liability: 

 

Prior to returning any unit, please provide a description of the failure or encountered problem(s), and consult with 
the Service Department at LaserPoint to avoid unnecessary shipments. 
LaserPoint  will,  at  its  sole  discrestion,  repair  or  replace  all  defective  parts  without  charge  to  the  customer; 
however, if LaserPoint determines that the failure was caused by misuse, alterations, an accident, or an abnormal 
operational condition or handling, then the customer will be billed for the repair and the repaired product will be 
returned, transportation and insurance prepaid by the customer. 
 

Содержание PcPlug-R

Страница 1: ...OPERATING MANUAL PcPlug R LASER POWER ENERGY METER rev03 16 07 2019 LaserPoint srl Via Burona 51 20090 Vimodrone Milano Italy Phone 39 02 27 400 236 Fax 39 02 25 029 161 www laserpoint eu ...

Страница 2: ... to Measure Single Shot Energy 7 9 INSTRUMENT SPECIFICATIONS 8 10 TROUBLESHOOTING 9 11 WARRANTY RE CALIBRATION AND RMA 10 12 1 Comprehensive Service for LaserPoint Products 10 12 2 Three Years Warranty Policy 10 12 3 Minor Repairs Policy 10 12 4 Annual Meter and Sensor Calibrations 10 12 5 Rapid Calibration Service 11 12 6 Re calibration Procedures and Timing 11 12 7 Return Material Authorization ...

Страница 3: ...aperture full scale hardness of its absorber What has to be measured laser power or laser energy Are the laser power energy and the power energy densities exceeding the sensor ratings See Sensor Specifications on http www laserpoint eu 2 Instrument Settings What settings have to be configured for example statistics energy threshold wavelength and so on 2 UNPACKING AND INSPECTION Each instrument ha...

Страница 4: ...r and other personal protective equipment must be used in compliance with applicable laws and safety regulations 1 The user of this instrument must be trained in the use of lasers and their associated risks LaserPoint is in no way liable for any damage resulting from misuse carelessness or use beyond the rated limits for the provided products 2 Complete all the required safety procedures to work w...

Страница 5: ... on the sensor disc The PcPlug R Electronics amplifies that voltage and its internal processing software elaborates the signal to display the level of power energy received by the sensor The software also reduces the signal rise time so that the display unit will respond faster to incoming signals Single pulse single shot Energy is calculated by the PcPlug R Electronics measuring the pulse integra...

Страница 6: ...awing and Dimensions 6 2 Serial Communication and Outputs The PcPlug R Electronics can be easily controlled by a PC or by an acquisition system A complete description of the settings and the communication commands can be found in the PcPlug R RS 232 Communication Interface document ...

Страница 7: ...f actions 1 Insert the RS 232 connector into the PC port 2 Run Serial Terminal SW or your own SW 3 Set the personal instrument settings Select the Measurement Range Zero the instrument and choose between the Power or Energy measurement mode For detailed instructions please refer to the PcPlug R RS 232 Communication Interface document 4 Verify the set wavelength Select the laser wavelength 5 Zero t...

Страница 8: ...of single pulses single shots or the total energy of multiple pulses burst pulse In fact consistently with the definition of Energy Thermopile Sensors integrate the power flowing through the sensor over the time Since the sensor can take up to several seconds to heat up and cool down Thermopile based heads are intrinsically slow and can measure one pulse every several seconds however since the mea...

Страница 9: ...D Resolution 23 bit ADC resolution 16 bit processing resolution Electrical accuracy 0 5 Electrical Input Noise 500 nV Input Offset Voltage drift 4 nV C typical Dynamic Range 8 decades Case Dimensions 78 x 26 4 x 14 6 mm H x W x D Weight 26 g DC in voltage 5 12 V through 2 1mm power connector positive inside Max 15 V DC in current 60 mA Operating Temperature Range 5 to 40 C Storage Temperature Rang...

Страница 10: ...nector Power or Energy reading is negative Select Power Mode make sure that the sensor housing is not hit by any laser thermal radiation and perform an instrument ZERO The measurements are different from previous expected values Verify that the laser beam is centered on the sensor Verify if the sensor coating shows signs of discoloration or damages contact LaserPoint The unit responds when head is...

Страница 11: ...sical damage improper installation and operation cleaning or un authorized maintenance misuse abuse modifications to the product not made by LaserPoint personnel software faults normal wear and tear or any other event act default or omission outside of the control of LaserPoint 12 3 Minor Repairs Policy LaserPoint provides more than the re calibration services Each time a sensor head or meter is s...

Страница 12: ...extended until all the information has been received 2 Shipment costs to and from LaserPoint are at the customer s expense 12 7 Return Material Authorization RMA Comply to our return and shipping policy conditions a LaserPoint product cannot be returned directly to LaserPoint without first asking for a Return Material Authorization RMA number b If the customer submits items when an RMA number has ...

Страница 13: ...r Energy meter is a product compliant to RoHS European Directive 15 WASTE OF ELECTRICAL ELECTRONIC EQUIPMENT 26 1 Information on Disposal of Electrical Electronic Equipment EUROPEAN UNION WEEE DIRECTIVE WEEE 2012 19 EU This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled to the local collecting points or giv...

Отзывы: